GD3126A (GD3126B) Rwb thaiv tsev Resistance Tester 5kV / 10TΩ (10kV / 20TΩ)

GD3126A (GD3126B) Rwb thaiv tsev Resistance Tester 5kV / 10TΩ (10kV / 20TΩ)

Cov lus piav qhia luv luv:

Nws yog qhov tsim nyog rau kev ntsuas kev tiv thaiv kev tiv thaiv hluav taws xob (IR), kev nqus qhov sib piv (DAR), polarization Performance index (PI), to tam sim no (Ix) thiab nqus capacitance (Cx) ntawm txhua yam khoom siv hluav taws xob siab, suav nrog switchgear, transformers, reactors, capacitors, motors, generators thiab cables, thiab lwm yam.

 


Product Detail

Khoom cim npe

Cov ntaub ntawv dav dav

GD3126A (GD3126B) Rwb thaiv tsev Resistance Tester yog dav siv hauv kev saib xyuas cov khoom siv hluav taws xob hauv transformer substation, fais fab nroj tsuag, thiab lwm yam. leakage tam sim no (Ix) thiab absorption capacitance (Cx) ntawm txhua yam khoom siv hluav taws xob siab, suav nrog switchgear, transformers, reactors, capacitors, motors, generators thiab cables, thiab lwm yam.

Nta

Adopts microcomputer tswj, cov ntawv qhia zaub mov ua haujlwm thiab loj LCD npo dot matrix zaub nrog kev ua haujlwm ruaj khov.
Muaj zog tiv thaiv kev cuam tshuam muaj peev xwm, haum rau kev ntsuas hauv qhov muaj zog electromagnetic cuam tshuam ib puag ncig.
Lub peev xwm loj, tuaj yeem ua tau raws li qhov yuav tsum tau muaj ntawm qhov siab voltage, siab tsis kam, lub peev xwm loj load test.
Nrog shockproof, ya raws-pov thawj thiab plua plav-pov thawj qauv, hloov mus rau qhov chaw ua haujlwm hnyav.
Tus neeg siv tus phooj ywg, tso saib cov txiaj ntsig raug thiab cov ntaub ntawv hloov pauv.
Kev tiv thaiv zoo tshaj plaws, muaj peev xwm tiv taus qhov cuam tshuam ntawm luv luv Circuit Court thiab ntsuas capacitance residual voltage.
5 voltage tso zis theem ntawm 250 V, 500V, 1.0kV, 2.5kV, 5.0kV.
6 voltage tso zis theem ntawm 250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV.Lub high voltage ntawm txhua kauj ruam yog tsis tu ncua adjustable los ntawm xoom.
Cov zis siab voltage kuj tuaj yeem hloov kho tas li.
Tsis siv neeg ntsuas ntawm R15, R60, R600, tsis siv neeg suav kev nqus piv, polarization Performance index.
Kev ntsuas qhov siab tshaj plaws yog 0 ~ 10TΩ (0 ~ 20TΩ), tsis siv neeg hloov ntau yam.
Tsis siv neeg ntsuas qhov kub thiab txias ambient, huab cua humidity thiab kuaj lub sij hawm.
Qhia lub sijhawm xeem, cov lus qhia buzz ntawm txhua 15 vib nas this, 5 feeb yam tsis muaj kev ua haujlwm yuav ua kom kaw.
Tsis siv neeg tawm hluav taws xob siab tom qab kev ntsuas tiav, lub sijhawm tso tawm tsis pub dhau 30 vib nas this.
Cia ntawm 60 pab pawg ntawm kev ntsuas cov txiaj ntsig, tsis muaj kev cuam tshuam rau 20 xyoo ..
Nrog RS232 serial interface, muaj peev xwm sib txuas lus nrog lub computer.
Nrog lub tshuab luam ntawv sab nraud, tuaj yeem luam tawm ntsuas ntsuas.(yeem)
Qhov hluav taws xob ntawm tus qauv them nqi yog qhia ua ntej kuaj thiab muaj cov lus qhia cuam tshuam.
Preset xeem lub sij hawm, cia li nres ntsuas;
Muaj peev xwm txheeb xyuas cov dej xau tam sim no Ix thiab nqus capacitance Cx.

Specifications

Rated test voltage theem

GD3126A (5kV) GD3126B (10kV)

250V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV

Output voltage yuam kev

± 5%

Kev tiv thaiv kab mob

Siab txwv

500 GΩ10T Ω

Tsawg txwv

0.1MΩ

Chav kawm raug

5.0 ib class

High voltage zaub yuam kev

± (5% •Ux + 1 digital)

Cov dej ntws tam sim no Ix ntsuas ntau & qhov yuam kev

0.1nA ~ 9.9mA 5%

Absorption capacitance Cx ntsuas ntau & yuam kev

0.1pF ~ 99ɥF 5%

Kev ntsuas kub yuam kev

± 0.5 ℃

Kev ntsuas dej tsis raug

± 2% RH

Short circuit tam sim no

<6mA

Voltage ripple

<3%

Lub sijhawm kuaj

Txog li 99 feeb

Rwb thaiv tsev tsis kam

> 500 MΩ (nruab nrab ntawm cov xov hlau thiab rooj plaub)

Nrog voltage

AC10.0kV 50Hz 1min (nruab nrab ntawm cov xov hlau thiab rooj plaub)

Fais fab mov

12V lithium roj teeb

Lub sijhawm ua haujlwm roj teeb tom qab ib qho kev them nyiaj

30 hnub 10 zaug DAR & 5 zaug PI xeem ib hnub

Ua haujlwm kub thiab av noo

0 ℃ ~ + 40 ℃ < 85% RH

Cia kub thiab av noo

-20 ℃ ~ + 50 ℃ < 90% RH

Fais fab mov

220V AC 50Hz

Qhov Loj (mm)

325 (L) * 250 (W) * 130 (H)

Qhov hnyav

3.7kg ib

Kev ntsuas qhov tsis kam

Voltage cov kauj ruam

250 V

500 V

1.0 kV ua

2.5kv :ua

5 ,0kv

10 KV

± (3% · Rx + 1d)

1 GΩ

2 GΩ

4 G Ω

10 GΩ

20 GΩ

40 g Ω

± (5% · Rx + 1d)

10 GΩ

20 GΩ

40 g Ω

0.1T Ω

0.2T Ω

0,4t 0

± (10% · Rx + 2d)

100 GΩ

200 GΩ

0,4t 0

1T Ω

2 TSI

4T Ω

± (25% Rx + 2d)

500 GΩ

1T Ω

2T Ω

5 t Ω

10T Ω

20T Ω

GD3126A (GD3126B) Cov Ntawv Teev Npe
Rwb thaiv tsev tiv thaiv tester 1set ib
Test txuas cable rau L davhlau ya nyob twg (Liab) 1 pob (1 pcs.)
Test txuas cable rau G davhlau ya nyob twg (ntsuab) 1 pob (1 pcs.)
Test txuas cable rau E davhlau ya nyob twg (Dub) 1 pob (1 pcs.)
3APower adapter (Rau lub tshuab luam ntawv fais fab mov thiab ntsuas ntsuas) 1 ib piece (1 daim)
RS232 Serial kev sib txuas lus kab 1 pob (1 pcs.)
Tus neeg siv's qhia 1 daim (1 daim)
Test Report 1 daim (1 daim)
Daim ntawv teev npe

Vaj Huam Sib Luag
1. L terminal socket 2. G terminal socket 3. E terminal socket 4. LCD npo
5. Buzzer 6. Kub & humidity sensor 7. ESC khawm 8. UP khawm
9. Contrast pob qhov rooj 10. Nias khawm 11. khawm OK12. High voltage kho pob qhov rooj
13. RS232 interface 14. Fais fab hloov15. Lub qhov (socket) them


  • Yav dhau los:
  • Tom ntej:

  • Xa koj cov lus rau peb:

    Sau koj cov lus ntawm no thiab xa tuaj rau peb

    Xa koj cov lus rau peb:

    Sau koj cov lus ntawm no thiab xa tuaj rau peb