GDHX-9700 Phase Detector

GDHX-9700 Phase Detector

Cov lus piav qhia luv luv:

GDHX-9700 Phase Detector yog siv rau hauv cov kab hluav taws xob hluav taws xob, theem, thiab theem ua ntu ntu calibration hauv substation, nrog cov haujlwm tseem ceeb suav nrog kev tshuaj xyuas hluav taws xob, theem calibration thiab ntsuas theem.


Product Detail

Khoom cim npe

Cov ntaub ntawv dav dav

GDHX-9700 Phase Detector yog siv rau hauv cov kab hluav taws xob hluav taws xob, theem, thiab theem ua ntu ntu calibration hauv substation, nrog cov haujlwm tseem ceeb suav nrog kev tshuaj xyuas hluav taws xob, theem calibration thiab ntsuas theem.Nws siv ob npaug thaiv thiab cov khoom lag luam tshiab digital circuits, muaj zog tiv thaiv kev cuam tshuam, ua raws li EMC cov qauv, tsim nyog rau ntau yam kev cuam tshuam hluav taws xob.

Lub high voltage theem teeb liab ntawm kev ntsuas cov hlau lead yuav raug xa mus ncaj qha tom qab kev kho mob, lub handset yuav tau txais thiab ua theem sib piv, txiav txim siab cov txiaj ntsig tom qab kuaj pom, real-time zaub theem qhov sib txawv thiab vector.Nws siv wireless kis tau tus mob technology, muaj kev nyab xeeb thiab txhim khu kev qha, ceev, thiab raug, haum rau siv nyob rau hauv txawv voltage theem (10V-500KV).Thaum kuaj xyuas cov qauv kab sib chaws, nws tuaj yeem txheeb xyuas qhov txheeb ze ntawm cov coj sib txawv rau cov kab sib txuas ntawm peb-theem, tsis muaj kev sib txuas hluav taws xob ntawm ob lub ntsuas ntsuas, uas ua rau daim ntawv thov ntawm cov ntsuas ntsuas tau yooj yim thiab nyab xeeb.

Nta

Voltage ntau: 10V ~ 500KV, muaj feem xyuam rau ntau qib voltage.
Qhov tseeb: luv luv: yuam kev ≤ ± 3 °;Kev ncua deb: yuam kev ≤ ± 3 °.
Sampling tus nqi: 10 zaug / thib ob.
Hnub thiab sijhawm teeb tsa, hnub thiab sijhawm hloov kho, yooj yim rau cov neeg siv los tshawb nrhiav, saib cov ntaub ntawv keeb kwm.
Backlight teeb: ib txwm rau, ib txwm tawm, tus neeg siv txhais tau li ntawm 0 ~ 999s.
Nws pib kaw: yeej tsis, tus neeg siv-txhais tau li ntawm 0 ~ 999 feeb.
Hauv-theem: ≤20 ° (tus neeg siv-txhais yog tias theem pib nyob rau hauv 0-90 °, default 20 °)
Tawm-theem:> 20 ° (tus neeg siv txhais tau tias theem pib nyob rau hauv 0-90 °, default 20 °)
On-site calibration muaj nuj nqi: on-site calibration tuaj yeem nqa tawm ntawm cov xov hlau kuaj kom paub meej qhov tseeb ntawm theem kaum.
Ntau hom tsim, siv tau zoo dua, ruaj ntseg dua, yooj yim dua.
Cim tib neeg-tshuab interface, ua haujlwm yooj yim.
FCC kav hlau txais xov tsim, muaj zog teeb liab, yooj yim rau nkag mus rau phab ntsa, qhov rooj, thiab thaiv.
Ob chav thaiv, muaj zog tiv thaiv kev cuam tshuam, ua raws li EMC cov qauv.
Cov kab kos thiab cov ntaub ntawv tso saib, nyeem yooj yim dua, nrog rau hnub thiab sijhawm tso saib ua haujlwm.
Kev ntsuas zoo: tso saib los ntawm acousto-optic teeb liab.
Kev ntsuas ntau: lub sijhawm ua haujlwm ntawm lub kaum ntse ntse sib txawv, qhov yuam kev ≤5 °.
Phase sequence check: theem zoo, theem tsis zoo (120°, 240°).
Nyob rau hauv GPS satellite sij hawm kev pab cuam, nrhiav kom pom qhov deb ntawm tus ntes Xa thiab Ya yog ≥500km.
Cov ntaub ntawv khaws cia muaj peev xwm ntawm 2000 pawg.Nws tuaj yeem nug thiab nkag mus rau cov ntaub ntawv keeb kwm.
Qhov ntev ntawm tus qauv rwb thaiv tsev pas nrig yog 4m, thiab qhov siv tau voltage qib ntawm rwb thaiv tsev pas nrig yog ≤ 220kV.

Technical Parameters

Voltage ntau

10V ~ 500kV 1

Fais fab mov

Hand-held unit: loj muaj peev xwm lithium roj teeb

Xa & Ya Detector:AA loj alkaline roj teeb (1.5V) 3pcs

Wireless kis tau tus mob

Visual nrug 150m

Hauv theem

≤20 ° (tus neeg siv-txhais yog tias theem pib nyob rau hauv 0-90 °)

Tawm-theem

>20 ° (tus neeg siv txhais tau tias theem pib nyob rau hauv 0-90 °)

Qhia qhov tseeb

Kev ntsuas qhov ntsuas ≤5 °

Kev daws teeb meem ntawm lub kaum sab xis

Kev ntsuas theem

Phase sequence yog txiav txim los ntawm clockwise 120 ° / counterclockwise 240 °

Satellite lub sijhawm sijhawm

2 ~ 30 feeb

Zaub

Zoo hom LCD npo, ntshiab nyob rau hauv lub hnub ci.

Ua haujlwm kub

-35 ~ + 50 ℃

Cia kub

-40 ~ + 55 ℃

txheeb ze humidity

≤ 95%RH, condensing

Handheld unit

0, 31 kg

Ntes Xa

0.16 kg ib

Ntes Ya

0.16 kg ib