GD3128 Series Rwb thaiv tsev Resistance Tester
GD3128 series Rwb thaiv tsev Resistance Tester muaj kev ua haujlwm zoo tshaj plaws ntawm ntau yam rwb thaiv tsev tsis zoo thiab muaj peev xwm tiv thaiv kev cuam tshuam zoo heev, uas tuaj yeem siv los ntsuas cov rwb thaiv tsev ntawm cov khoom siv hluav taws xob muaj peev xwm loj thiab cov kab sib txuas hauv qhov chaw muaj zog inductive xws li substation.Cov cuab yeej siv qhov tseeb xim kov lub vijtsam, tag nrho cov ntaub ntawv xeem thiab lub roj teeb lub zog tau tshwm sim ntawm tib lub vijtsam ntawm ib sab, thiab kev sib txuas ntawm cov pob qhov rooj thiab qhov tseem ceeb ua rau kev ua haujlwm yooj yim heev.Tus neeg siv tsis tas yuav cim cov txheej txheem ua haujlwm.Nyem "HELP" ntawm qhov screen kom pop txog cov txheej txheem kev ua haujlwm, uas tuaj yeem coj tus neeg siv kom ua haujlwm tau zoo.Lub ntsuas hluav taws xob muaj lub luag haujlwm ntawm kev xa tawm sai, uas tuaj yeem tso tawm qhov hluav taws xob ntawm cov khoom kuaj tam sim ntawd yam tsis muaj qhov hluav taws xob ntxiv.Lub ntsuas hluav taws xob ntawm lub ntsuas hluav taws xob tuaj yeem saib xyuas qhov hluav taws xob nyob ntawm qhov khoom kuaj.Yog tias qhov hluav taws xob ntau tshaj 36V, qhov kev ntsuam xyuas yuav raug txwv tsis pub, uas tuaj yeem tiv thaiv cov cuab yeej thiab cov neeg ua haujlwm zoo.
Cov cuab yeej siv lub peev xwm loj rechargeable lithium roj teeb pob.Lub sijhawm ntsuas ntsuas ntawm lub ntsuas ntsuas cia li sau lub sijhawm xeem thiab khaws cov ntawv xeem nrog hnub thiab sijhawm.Lub vijtsam kov tau yooj yim nkag mus rau cov ntaub ntawv keeb kwm kaw.Qhov kev sib cais tag nrho USB interface tuaj yeem muaj kev nyab xeeb xa cov ntaub ntawv xeem mus rau PC.Lub ntsuas hluav taws xob tau nruab nrog cov kab ntsuas nrog ob txheej rwb thaiv tsev thiab thaiv txheej, thiab lub zog hluav taws xob siab yog nruab nrog cov hlua khi thiab nuv, uas tuaj yeem hloov mus rau ntau qhov chaw sim.Cov cuab yeej siv cov txheej txheem ob txheej txheej plhaub, thiab qib kev tiv thaiv ntawm lub thawv sab nrauv yog IP65, uas tuaj yeem tiv thaiv kev cuam tshuam ntawm ya raws thiab plua plav thaum thauj thiab khaws cia, thiab tiv thaiv cov cuab yeej los ntawm kev sib tsoo.
GD3128 series muaj ntau yam, kev daws teeb meem siab, kev ua haujlwm yooj yim, ruaj khov thiab ua haujlwm ntev, qhov tseeb thiab kev ntseeg siab, kev ua haujlwm ruaj khov, thiab muaj peev xwm tiv thaiv kev cuam tshuam.Cov cuab yeej muaj kev ntsuas hluav taws xob tiv thaiv (IR);polarization index test (PI);absorption ratio test (DAR);ramp test (RAMP);filter test (FR, 10S, 20S, 30S, 40S plaub xaiv);ntsuas hluav taws xob (V);capacitance test (uF);kev sim tam sim no (nA) thiab lwm yam haujlwm.Cov twj paj nruag yog tsim rau kev ntsuas kev tiv thaiv hluav taws xob ntawm cov khoom siv hluav taws xob, cov kab sib kis thiab lwm yam khoom siv loj nyob rau hauv ib puag ncig ntawm lub peev xwm loj, siab voltage thiab muaj zog induction.Nws yog ib qho cuab yeej siv thiab tseem ceeb rau hluav taws xob hluav taws xob, kev sib txuas lus, huab cua, chav tsev computer, roj av, hluav taws xob thiab kev kho hluav taws xob, thiab chaw ua haujlwm fais fab ntawm cov chaw lag luam thiab mining.
●Qhov siab tshaj plaws luv luv tam sim no yog 7mA.
●Rwb thaiv tsev tiv thaiv (IR), polarization index test (PI), nqus piv piv (DAR).
●Ramp test hom (RAMP), lim test hom (FR), capacitance test (uF)
●Voltage monitor muaj nuj nqi, cia li saib xyuas cov nqi hluav taws xob ntawm cov khoom kuaj.
●Test timer muaj nuj nqi, cia li sau lub sij hawm xeem.
●Tsis siv neeg tso tawm muaj nuj nqi, cia li thiab sai sai tso tus nqi ntawm cov khoom kuaj tom qab qhov kev xeem, tsis muaj ib tug sab nraud paug Circuit Court.
●Tsis siv neeg kaw muaj nuj nqi.
●Loj kov xim npo.
●Ob txheej txheej plhaub qauv, ruaj khov thiab ruaj khov, tiv thaiv qib IP65.
●High-capacity rechargeable lithium roj teeb pob.
●Kev khaws cia muaj nuj nqi, tuaj yeem khaws 1000 pawg ntawm cov ntaub ntawv kuaj lub sijhawm nrog rau hnub xeem thiab sijhawm thiab sijhawm kuaj.
●Upload muaj nuj nqi, nruab nrog USB interface, cov ntaub ntawv cov ntaub ntawv tuaj yeem xa mus rau lub computer rau kev txheeb xyuas cov ntaub ntawv.
Yam khoom Model | Rated Voltage | Rwb thaiv tsev Resistance Range | Short Circuit Current |
wb 3128A | 250 V,500 V,1kV,2.5kV,5kV | 0.50MΩ ~ 10.0TΩ | ≥7mA |
GD3128B | 250 V,500 V,1kV,2.5kV,5kV, 10 kV | 0.50MΩ ~ 20.0TΩ | ≥7mA |
GD3128C | 250 V,500 V,1kV,2.5kV,5kV, 10kV , 15kV | 0.50MΩ ~ 30.0TΩ | ≥7mA |
Rwb thaiv tsev Resistance Range thiab raug
Rated Voltage | Insulation Resistance Rage | Qhov tseeb | Lus ceeb toom |
250 V | 0.50MΩ~50.0G Ω | ± 5% rdg ± 3dgt |
|
50.0G Ω~500 GΩ | ± 20% rdg ± 3dgt |
| |
500 V | 1.00MΩ~100 GΩ | ± 5% rdg ± 3dgt |
|
100 GΩ~1.00 TSI | ± 20% rdg ± 3dgt |
| |
1000V | 1.00MΩ~200 GΩ | ± 5% rdg ± 3dgt |
|
200 GΩ~2.00 TSI | ± 20% rdg ± 3dgt |
| |
2500V | 1.00MΩ~500 GΩ | ± 5% rdg ± 3dgt |
|
500 GΩ~3.00 TSI | ± 20% rdg ± 3dgt |
| |
5000V | 1.00MΩ~1.00 TSI | ± 5% rdg ± 3dgt |
|
1.00 TSI~10.0T Ω | ± 20% rdg ± 3dgt |
| |
10 KV | 1.00MΩ~2.00 TSI | ± 5% rdg ± 3dgt |
|
2.00 TSI~20.0T Ω | ± 20% rdg ± 3dgt |
| |
15 KV | 1.00MΩ~3.00 TSI | ± 5% rdg ± 3dgt |
|
3.00 TSI~30.0T Ω | ± 20% rdg ± 3dgt |
1 TΩ (Tera ohm) = 1000GΩ = 1012Ω
1 GΩ (Giga ohm) = 1000MΩ = 109Ω
1 MΩ (Mega ohm) = 1000KΩ = 106Ω
Muaj nuj nqi | Rwb thaiv tsev ntsuas (IR);polarization index ntsuas (PI);nqus piv (DAR);ramp test hom (RAMP);limmuaj nuj nqi(10S, 20S, 30S, 40S);voltage ntsuas (V);kabtancentsuas(uF);kev ntsuas tam sim no(nA) |
Fais fab mov | Rechargeable lithium roj teeb 6.2Ah |
Rated Voltage | wb 3128A: 250 V, 500 V, 1kV, 2.5kV, 5kV GD3128B: 250 V, 500 V, 1kV, 2.5kV, 5kV, 10kV GD3128C: 250 V, 500 V, 1kV, 2.5kV, 5kV, 10kV, 15kV |
Output Voltage raug | (5%~10%) ± 10V |
Rwb thaiv tsev Resistance Test Range | wb 3128: 0.50MΩ~10.0T Ω GD3128B: 0.50MΩ~20.0T Ω GD3128C: 0.50MΩ~30.0T Ω |
Output Short Circuit Current | ≥7mA |
Polarization Index Test | Yog lawm |
Absorption Ratio Test | Yog lawm |
Ramp Test Hom | Kuaj nyob rau hauv cov kauj ruam ntawm 10% ntawm preset voltage kom txog rau thaum lub preset voltage. |
Lim Test Hom | 10S, 20S, 30 S, 40S plaub xaiv. |
Kev ntsuas hluav taws xob | Ntau yam: AC / DC: 0V~1000V; Qhov tseeb: ± 5% rdg ± 3V |
Kev Xeem Capacitance | Ntau yam: 10 nF~25 uaf; Qhov tseeb: ± 10% rdg ± 10nF |
Kev sim tam sim no | Ntau yam: 0,01n ua~7mA ua; Qhov tseeb: ± 5% rdg ± 0.5nA |
Voltage Monitor | Saib xyuas qhov voltage ntawm lubtesd khoom, thiab saib xyuas cov xwm txheej tawm tom qab kuaj, txwv tsis pub kuaj thaum muaj hluav taws xob ntau tshaj 36V, tiv thaiv cov cuab yeej thiab tus neeg teb xov tooj. |
Test Timer | Automatic record test time, timhauvqib: 0s9999 |
Cia muaj nuj nqi | Cia li khaws cov ntaub ntawv xeem nrog hnub xeem thiab sijhawm, tag nrho ntawm 1000 pawg |
Upload Function | Upload cov ntaub ntawv khaws cia rau lub computer ntawm USB kev sib txuas lus cable. |
Battery Power Display | Nrog roj teeb lub zog tso saib, thaum lub roj teeb voltage qis yuav ceeb toom raunqilub roj teeb. |
Tsis siv neeg kaw | Tom qab 15 feeb pib yuav kaw cia li tsis ua haujlwm. |
Dimension | 280mm × 260mm × 160mm |
Qhov hnyav | 4900g (nrog rau lub roj teeb) |
Test Hlau | Liab xim high voltage kuaj hlau 1pc (nroga Alligator clip thiab nuv), ntsuab xim kuaj hlau 1pc, dub xim kuaj hlau 1pc |
Qib tiv thaiv | Kaw rooj plaub IP65, qhib rooj plaub IP40 |
Ua haujlwm ib puag ncig | -20 ℃~50 ℃; 80% rh |
Khw ib puag ncig | -25 ℃~65 ℃; 80% rh |
Rwb thaiv tsev Resistance | 50MΩ(1000V) (nruab nrab ntawm lub xeem Circuit Court thiab plhaub) |
Nrog Voltage | AC 3kV50Hz 1 min(nruab nrab ntawm lub xeem Circuit Court thiab plhaub) |
Kev nyab xeeb | IEC 61010-1, IEC 61326-1 |