GD3126A (GD3126B) Rwb thaiv tsev Resistance Tester 5kV / 10TΩ (10kV / 20TΩ)
Nws yog qhov tsim nyog rau kev ntsuas qhov ntsuas hluav taws xob tiv thaiv (IR), qhov sib nqus nqus (DAR), polarization Performance index (PI), to tam sim no (Ix) thiab nqus capacitance (Cx) ntawm txhua yam khoom siv hluav taws xob siab, suav nrog switchgear, transformers, reactors, capacitors, motors, generators thiab cables, thiab lwm yam.
-
GD2000H 10kV Rwb thaiv tsev Resistance Tester
Cov cuab yeej no tuaj yeem kuaj cov rwb thaiv tsev tiv thaiv (xws li transformer, switchgear, leads, motor) ntawm cov qauv sib txawv hauv ib qho system, txhawm rau tiv thaiv thiab kho cov khoom tsis ua haujlwm.
-
GD3127 Series High Voltage Rwb thaiv tsev Resistance Tester
GD3127 Series Rwb thaiv tsev Resistance Tester yog dav siv hauv kev saib xyuas cov khoom siv hluav taws xob hauv transformer substation, fais fab nroj tsuag, thiab lwm yam.
-
GDHX-9500 Phase Detector
GDHX-9500 Phase Detector yog tsuas yog siv rau hauv cov kab hluav taws xob, theem thiab theem ua ntu zus calibration hauv substation, nrog rau lub luag haujlwm tseem ceeb suav nrog kev tshuaj xyuas hluav taws xob, theem calibration thiab kev ntsuas theem.
-
GDHX-9700 Phase Detector
GDHX-9700 Phase Detector yog siv rau hauv cov kab hluav taws xob hluav taws xob, theem, thiab theem ua ntu zus calibration hauv substation, nrog rau lub luag haujlwm tseem ceeb suav nrog kev tshuaj xyuas hluav taws xob, theem calibration thiab kev ntsuas theem.
-
GDCR1000C Tsis tiv tauj Theem Sequence Tester
GDCR1000C, GDCR1000D non-contact tester yog ib qho kev ua tiav loj hauv cov txheej txheem kev kuaj xyuas theem ib txwm.
-
GD2000D Rwb thaiv tsev Resistance Tester
GD2000D digital rwb thaiv tsev tsis kam tester ua los ntawm peb lub tuam txhab siv ib tug embedded industrial ib nti ntawm lub sijhawm ua haujlwm.Cov digital analog pointer thiab digital field code tso saib ua ke zoo kawg nkaus.
-
GDDT-10U Digital Grounding Down Lead Earth Continuity Tester
GDDT-10U Earth Continuity Resistance Tester yog cov khoom siv ntsuas tsis siv neeg thiab nqa tau yooj yim.Nws yog siv rau kev ntsuas ntawm breakover kuj tus nqi ntawm lub ntiaj teb txuas cables ntawm substation hluav taws xob khoom.
-
GDF-3000 DC System Earth Fault Detector
Nyob rau hauv DC system, muaj ntau lub ntiaj teb faults xws li indirect lub ntiaj teb txhaum, tsis yog-hlau lub ntiaj teb txhaum, voj lub ntiaj teb txhaum, zoo thiab tsis zoo earthing txhaum, zoo thiab tsis zoo tshuav lub ntiaj teb txhaum, ntau lub ntiaj teb txhaum.
-
GDCR3000 Digital Earth Resistance Tester
Nws yog dav siv hauv hluav taws xob hluav taws xob, kev sib txuas lus, huab cua, roj av, kev tsim kho, kev tiv thaiv hluav taws xob, cov khoom siv hluav taws xob thiab lwm yam kev ntsuas hauv av.
-
GDWR-5A Earth Resistance Tester rau Daim phiaj av
GDWR-5A Earth Resistance Tester yog cov cuab yeej ntsuas qhov ntsuas siab siv hauv ntau qhov chaw xws li cov chaw nres tsheb rau kev ntsuas av tiv thaiv thiab lwm yam.Cov cuab yeej muaj cov yam ntxwv ntawm cov ntim me me, lub teeb yuag, nqa tau yooj yim, muaj zog tiv thaiv kev cuam tshuam kev ua haujlwm thiab qhov raug siab.
-
Kev soj ntsuam hauv online ntawm Circulating Tam sim no ntawm Cable Sheath GDCO-301
Cov kab hluav taws xob siab tshaj 35kV feem ntau yog ib leeg-core cables nrog hlau sheath.Txij li cov hlau sheath ntawm ib leeg-core cable yog hinged nrog cov magnetic teb kab generated los ntawm AC tam sim no nyob rau hauv cov tub ntxhais hlau, ob kawg ntawm ib tug tub ntxhais cable muaj ib tug high induced voltage.