GD2000D Rwb thaiv tsev Resistance Tester
GD2000D digital rwb thaiv tsev tiv thaiv tester ua los ntawm peb lub tuam txhab siv ib tug embedded industrial ib nti ntawm lub sijhawm ua haujlwm.Cov digital analog pointer thiab digital field code zaub tau ua ke zoo kawg nkaus.Qhov no series ntawm meters muaj ntau yam voltage tso zis ntau ntau (250V, 500V, 1000V, 2500V, 5000V, 10000V), muaj peev xwm loj, muaj zog tiv thaiv kev cuam tshuam, analog pointer thiab digital synchronous zaub, AC thiab DC dual-siv, kev ua haujlwm yooj yim, Tsis siv neeg suav ntawm ntau yam kev ntsuas rwb thaiv tsev (kev nqus piv, polarization Performance index), ntau yam kev ntsuas nrog kev tiv thaiv lub zog-down muaj nuj nqi, thiab lwm yam. hluav taws xob motors, lub hwj chim capacitor, fais fab cables, thiab xob laim ntes.
DL/T 474-2006 "Cov Lus Qhia rau Kev Ntsuas Hluav Taws Xob ntawm qhov chaw"
DL / T 845-2004 "Cov lus qhia dav dav rau ntsuas cov khoom siv tiv thaiv"
DL / T 846-2004 "Cov kev qhia tshwj xeeb rau cov khoom siv hluav taws xob siab"
DL/T 596-2005 "Kev Tiv Thaiv Kev Ntsuas Cov Khoom Siv Hluav Taws Xob"
GB50150-2006 "Standard for hand-over test of electric equipment electric equipment installation engineering"
GB / T16927.1 ~ 2-1997 "Cov txheej txheem ntsuas hluav taws xob siab"
GB4793-1984 "Kev sib koom ua ke ntawm rwb thaiv tsev rau cov khoom siv hluav taws xob siab thiab cov khoom xa tawm"
1. Voltage tso zis (250V / 500V / 1000V / 2500V / 5000V).Resistance range 0-200GΩ.
2. Ob hom tso saib rwb thaiv tsev tsis kam.
3. Auto-calculating absorption ratio thiab polarization Performance index.
4. Kev ua haujlwm zoo, tsis tu ncua txuag 19 zaug ntsuas kev ntsuas.
5. Auto-discharge residual high voltage tom qab xeem dhau lawm.
6. AC / DC fais fab mov, nrog rau cov roj teeb rechargeable lossis AC adapter.
7. Muaj zog tiv thaiv kev cuam tshuam, kev nyeem ntawv ruaj khov thiab txhim khu kev qha.
8. Portable tsim, haum rau kev ua haujlwm qus.
9. Lub caij luv luv tam sim no ≥3mA, cov cuab yeej zoo tshaj plaws rau kev ntsuas kev tiv thaiv hluav taws xob ntawm cov hluav taws xob loj, inductor, generator, HV motors, hluav taws xob capacitor, cables thiab surge arrester.
Yam khoom No. | GD2000D | ||||||
Output voltage | 250V DC fais fab mov | 500V DC fais fab mov | 1000V DC fais fab mov | 2500V DC fais fab mov | 5000V DC fais fab mov | ||
Qhov tseeb | Kub | 23 ℃ ± 5 ℃ | |||||
Rwb thaiv tsev tsis kam | 250-5G ± 5% | 50-10G ± 5% | 1M-20G ± 5% | 2.5M-50G ± 5% | 5M-100G ± 5% | ||
Lwm qhov ntau: ± 10% | |||||||
Output voltage | 2M-10G ± 5% | 4M-20G ± 5% | 8M-40G 0--+10% | 20-100G Ω 0 --+10% | 40-200g 0 - +10% | ||
Short-circuit tam sim no | ≥3mA | ||||||
Fais fab mov | 8*AA hom muaj peev xwm rechargeable roj teeb & sab nraud adapter | ||||||
Ua hauj lwm Temp. & Humidity | -10 ℃ --- 40 ℃, max.relative humidity 85% | ||||||
Cia Temp. & Humidity | -20 ℃ --- 60 ℃, max. txheeb ze humidity 90% | ||||||
Rwb thaiv tsev | Max.2000MΩ thaum voltage ntawm Circuit Court thiab plhaub yog 1000VDC. | ||||||
Nrog voltage | Nrog 1min thaum voltage ntawm Circuit Court thiab plhaub yog3kV50Hz SineAC voltage | ||||||
Dimension | 230mm * 190mm * 90mm (L * W * H) | ||||||
Qhov hnyav | 3kg ua |
Rwb thaiv tsev tiv thaiv tester | 1set ib |
Test hlau | 1 qob |
Fais fab adapter | 1 qob |
Fais fab qaum | 1 qob |
Tus neeg siv phau ntawv qhia | 1 luam |
Daim ntawv pov thawj | 1 luam |