Transformer Test Equipment

  • GDB-D Transformer Tig Ratio Tester

    GDB-D Transformer Tig Ratio Tester

    GDB-D Transformer tig ratio tester yog tsim los rau peb theem transformer nyob rau hauv lub hwj chim system thiab tshwj xeeb tshaj yog rau Z hom winding transformer thiab lwm yam transformers nrog kuj loj tsis muaj load tam sim no.

  • GDB-H Handheld Automatic Transformer Tig Ratio Tester

    GDB-H Handheld Automatic Transformer Tig Ratio Tester

    Nws tuaj yeem ntsuas qhov sib piv, pawg thiab theem kaum sab xis, uas yog tsim rau txhua hom kev hloov pauv xws li Z hom transformers, rectifier transformers, hluav taws xob rauv transformers, theem-hloov transformers, traction transformers, scott thiab invert-scott transformers.

  • GDB-IV Peb Theem Transformer Tig Qhov Ntsuas Tester

    GDB-IV Peb Theem Transformer Tig Qhov Ntsuas Tester

    Lub zog sab hauv module nyob rau hauv lub tester generates peb-theem fais fab los yog ob-theem fais fab, uas yog tso tawm mus rau high voltage sab ntawm lub transformer.Tom qab ntawd qhov hluav taws xob siab thiab qhov hluav taws xob tsawg yog kuaj tib lub sijhawm.Thaum kawg, pab pawg, piv txwv,yuam kev,thiab theem sib txawv yog xam.

     

     

     

     

     

     

  • GD6900 Capacitance thiab Dissipation Factor Tester

    GD6900 Capacitance thiab Dissipation Factor Tester

    GD6900 ntsuas qhov capacitance thiab dielectric poob yam tseem ceeb (tgδ) ntawm cov khoom siv hluav taws xob siab.Nws yog integrated qauv, built-in dielectric poob xeem choj, sib txawv zaus adjustable fais fab mov, boosting transformer thiab SF6 txheem capacitor.

     

  • GDZRC Series DC Winding Resistance Tester (GDZRC-10A)

    GDZRC Series DC Winding Resistance Tester (GDZRC-10A)

    GDZRC-10A

    GDZRC series DC winding kuj testeryog tsim los ntsuas DC tsis kam ntawm inductivekhoom siv, xws li transformers thiab hwj chim inductors.
    Nws muaj cov yam ntxwv ntawm kev ntsuas ceev, me methiab siab raug ntawm kev ntsuas, uas yog cov khoom siv zoo tagnrhontawm ntsuas transformer winding thiab DC tsis kam ntawmloj zog inductance khoom.

     

  • GD6800 Capacitance thiab Dissipation Factor Tester

    GD6800 Capacitance thiab Dissipation Factor Tester

    gd6800 ibsa tag nrho automatic 10kV rwb thaiv tsev fais fab/dissipation factor (tan∂) xeemertsim los rau kev soj ntsuam ntawm hluav taws xob rwb thaiv tsev nyob rau hauv high voltage apparatus xws li transformers, bushings, Circuit Court breakers, cables, xob laim ntes thiab rotating machinery.

     

     

     

     

  • GDZRS-20A Peb Theem DC Winding Resistance Tester

    GDZRS-20A Peb Theem DC Winding Resistance Tester

    Qhov no DC tiv thaiv ceev tester (tom qab no hu ua DC winding resistance tester) yog cov khoom tsim tshiab tshaj plaws rau kev ntsuas DC tsis kam ntawm transformers.Nws yog optimized rau ntsuas DC tsis kam ntawm peb-theem windings ntawm loj-muaj peev xwm transformers.DC tsis kam ntawm peb-theem windings ntawm lub transformer tuaj yeem kuaj ib txhij.Rau cov khoom siv hluav taws xob hluav taws xob tswj hluav taws xob, nws tsis tas yuav tso tawm cov kais hloov pauv ncaj qha, thiab lub sijhawm ntsuas yog ib feem peb ntawm kev ntsuas ib ntus ib txwm, uas tuaj yeem txo lub sijhawm ua haujlwm thiab kev siv zog ntau.Lub ntsuas hluav taws xob ncaj qha txais lub vijtsam loj-screen kua siv lead ua zaub, tag nrho Suav graphical interface, meej thiab nkag siab, thiab kev ua haujlwm yooj yim heev.Thiab nruab nrog lub tshuab luam ntawv vaj huam sib luag thiab lub peev xwm loj uas tsis yog-volatile nco, koj tuaj yeem yooj yim khaws thiab luam tawm cov txiaj ntsig ntsuas.Cov ntaub ntawv xeem yog ruaj khov, ceev thiab rov ua dua, thiab nws yog qhov kev xaiv zoo tshaj plaws rau kev ntsuas DC tsis kam ntawm transformers ntawm qhov chaw.

  • GD6100 Rwb thaiv tsev Roj Tan Delta Tester (Oil Dissipation Factor Tester)

    GD6100 Rwb thaiv tsev Roj Tan Delta Tester (Oil Dissipation Factor Tester)

    GD6100 yog cov cuab yeej siv high-precision rau kev sim dielectric poob lub kaum sab xis thiab ntim resistivity ntawm insulating roj los yog lwm yam insulating kua.

  • GDOT-80A IEC Standard rwb thaiv tsev roj tawg Tester 80kV

    GDOT-80A IEC Standard rwb thaiv tsev roj tawg Tester 80kV

    Muaj ntau cov khoom siv hluav taws xob hauv lub zog hluav taws xob, txoj kev tsheb ciav hlau thiab cov chaw ua haujlwm loj petrochemical mines thiab cov lag luam, lawv cov rwb thaiv tsev sab hauv feem ntau yog cov roj ntim roj.Lub zog dielectric ntawm cov roj insulating yog qhov yuav tsum tau ua txhua hnub.Txhawm rau ua kom tau raws li qhov xav tau ntawm kev ua lag luam, peb lub tuam txhab tsim thiab tsim cov roj dielectric dielectric zog testers raws li lub teb chaws tus qauv GB / T507-2002 (IEC156), tus qauv DL429.9-91 thiab qhov tseeb fais fab kev lag luam tus qauv. DL/T846.7-2004.Cov cuab yeej no siv lub microcomputer ib leeg ua lub hauv paus, paub txog tag nrho cov kev ntsuas automation, muaj kev ntsuas siab, txhim kho kev ua haujlwm zoo, thiab txo qis kev siv zog ntawm cov neeg ua haujlwm.Nyob rau tib lub sijhawm, cov cuab yeej muaj lub ntsej muag compact thiab yooj yim rau nqa.

  • GDOT-80A rwb thaiv tsev roj Tester

    GDOT-80A rwb thaiv tsev roj Tester

    Thov nyeem phau ntawv ua haujlwm kom zoo ua ntej ua haujlwm.
    Thov xyuas seb tus tester puas txuas nrog lub ntiaj teb ua ntej kuaj.
    Nws yog txwv tsis pub txav los yog nqa lub npog ntsuas hauv cov txheej txheem ntawm kev sim kom tsis txhob raug mob los ntawm qhov hluav taws xob siab.Lub hwj chim yuav tsum tau muab tshem tawm ua ntej hloov cov qauv roj.

  • GDKC-5000 Transformer Ntawm Load Kais Changer Tester

    GDKC-5000 Transformer Ntawm Load Kais Changer Tester

    GDKC-5000 Transformer On Load Tap Changer Tester tuaj yeem ntsuas lub sijhawm hloov pauv, hloov pauv hloov pauv, hloov pauv hloov pauv, peb-theem synchronization thiab lwm yam tsis zoo ntawm cov khoom siv hloov pauv.Nws yog ib qho khoom siv zoo tshaj plaws rau kev kuaj load kais hloov pauv.Nws ua tau raws li qhov yuav tsum tau ua ntawm kev txheeb xyuas qhov ua ntu zus ntawm kev thauj khoom kais hloov pauv thiab ntsuas lub sijhawm hloov pauv.

     

  • GDBT-1000kVA Transformer Test Bench

    GDBT-1000kVA Transformer Test Bench

    GDBT Transformer test system tuaj yeem ua txhua qhov kev sim niaj hnub rau kev hloov pauv, suav nrog Tsis muaj kev thauj khoom thiab thauj khoom, Kev ntsuas hluav taws xob, Lub zog zaus tiv thaiv qhov ntsuas hluav taws xob, kuaj ib nrab, DC tsis kam kuaj, ntsuas piv piv, ntsuas kub nce thiab lwm yam.