Dab tsi yog kev ceev faj rau kev siv zinc oxide ntes tester?

Dab tsi yog kev ceev faj rau kev siv zinc oxide ntes tester?

Zinc oxide Surge Arrester Tester yog ib qho cuab yeej rau kev ntsuas kev ua haujlwm ntawm cov khoom siv zinc oxide ntes.Nws tuaj yeem kuaj xyuas lub zog tsis ua haujlwm lossis nyob hauv lub xeev, thiab tuaj yeem tshawb xyuas raws sijhawm seb tus zinc oxide ntes puas yog laus lossis ntub dej.Nws muaj qhov ntsuas qhov tseeb.Kev siv thiab kev ua haujlwm yog qhov yooj yim thiab yooj yim, thiab tau siv dav hauv ntau qhov chaw.Niaj hnub no, HV Hipot yuav muab cov ncauj lus qhia ntxaws ntxaws rau kev ceev faj rau kev siv cov zinc oxide ntes tus ntes.

                                                                                 氧化锌避雷器综合测试仪

                                                                                                                                 GDYZ-301 zinc oxide Surge arrester tester

1. Nyob rau hauv cov xwm txheej ntawm cov tswv yim tam sim no thiab cov khoom siv hluav taws xob, nco ntsoov tsis txhob ntsaws thiab tshem tawm cov ntsuas ntsuas kom tsis txhob muaj zinc oxide ntes cov ntsuas ntsuas los ntawm kev hlawv tawm.

2. Nco ntsoov tsis txhob txuas cov input kab ntawm lub teeb liab tam sim no thiab cov input kab ntawm lub teeb liab voltage nyob rau hauv thim rov qab.Yog tias cov kab ntawv nkag ntawm lub teeb liab tam sim no txuas nrog qhov ntsuas qhov kawg ntawm qhov ntsuas transformer, nws yuav ua rau cov cuab yeej hlawv tawm thiab cuam tshuam rau kev ua haujlwm ib txwm muaj.

3. Thaum PT tau txais qhov kev siv hluav taws xob thib ob, cov xov hluav taws xob yuav tsum tau ua tib zoo xyuas kom tsis txhob muaj qhov tshwm sim ntawm kev sib tsoo luv luv.

4. Lub ntsuas zinc oxide ntes yuav tsum tsis txhob muab tso rau hauv qhov kub thiab txias los tiv thaiv kev ya raws lossis kev puas tsuaj.

5. Yog tias koj pom tias cov cuab yeej ua haujlwm txawv txav, koj yuav tsum xub xyuas cov ntawv pov hwm fais fab kom pom tias nws muaj qhov tshwm sim fuse.Yog tias koj pom tias cov cuab yeej puas lawm, tsis txhob kho koj tus kheej, thiab nco ntsoov hu rau lub chaw tsim khoom ntawm zinc oxide arrester tester hauv lub sijhawm..Qhov kev sim tsuas tuaj yeem txuas ntxiv tom qab lub fuse ntawm tib hom tau hloov.

6. Thaum lub sij hawm kev sib txuas, tsis txhob txuas cov kab hluav taws xob thiab cov qauv tam sim no rov qab los yog tsis ncaj ncees lawm, thiab thaum lub sij hawm sim, lub series-excited test transformer tsis tuaj yeem siv rau cov khoom siv hluav taws xob siab;Nyob rau tib lub sijhawm, nws yog ib qho tsim nyog los tiv thaiv luv luv ntawm qhov tshwm sim..

Zinc oxide arrester tester yog tswj los ntawm ib tug ib-chip microcomputer, uas muaj peev xwm tso saib cov waveforms tiag tiag ntawm tam sim no thiab voltage, thiab cov kev ntsuas tau ruaj khov thiab raug;thaum koj siv nws, koj yuav tsum xyuam xim rau cov ntsiab lus saum toj no, thiab ua tib zoo saib xyuas txhua yam.Ua tib zoo ua kom tsis txhob muaj xwm txheej.