Lub high-voltage wireless theem nuclear detector muaj zog tiv thaiv kev cuam tshuam kev ua tau zoo, ua tau raws li cov kev cai ntawm (EMC) cov qauv, thiab yog haum rau ntau yam electromagnetic teb cuam tshuam lub sij hawm.Qhov ntsuas high-voltage theem teeb liab raug coj tawm los ntawm tus neeg sau, ua tiav thiab xa tawm ncaj qha.Nws tau txais los ntawm theem ntsuas thiab muab piv nrog rau theem, thiab qhov tshwm sim tom qab theem yog qhov zoo.Vim tias cov khoom no yog kev sib txuas lus wireless, nws muaj kev nyab xeeb tiag tiag, txhim khu kev qha, nrawm thiab raug, thiab tsim nyog rau ntau lub sijhawm.
Cov theem yog qhov txuas tseem ceeb heev hauv hluav taws xob engineering.Lub high-voltage wireless theem ntsuas yog cov theem ntsuas siv, uas yog lub teeb, ceev thiab raug.Feem ntau, thaum siv, cov theem cores nyob rau hauv tib lub voltage, uas yog undoubtedly tsis muaj teeb meem.Ntxiv nrog rau qhov kev txheeb xyuas theem ib txwm nyob rau tib theem voltage, lub high-voltage wireless theem pov thawj ntsuas kuj tseem siv tau thoob plaws qib voltage!
GDHX-9500 wireless high voltage theem ntes
Phase detector test method:
1. Sab hauv tsev calibration txoj kev
ib.Tshem tawm lub transmitter X thiab transmitter Y thiab txuas cov zis pas nrig (built-in transmitting kav hlau txais xov), thiab txuas lub transmitter X thiab transmitter nuv nrog ob lub me me clips ntawm ib kawg ntawm cov kab xeem muab los ntawm lub ntsuas.Tom qab ib kawg yog ntsaws rau hauv 220V fais fab mov (vim tias 220V ib-theem nyob xaim hloov mus rau ob chav nyob, qhov hluav taws xob tsawg), tig lub hwj chim hloov ntawm lub receiver.Tom qab lub waveform tshwm, qhov ntsuas tuaj yeem suav tias yog qhov qub.
2. Kev siv ntawm qhov chaw
ib.Ua ntej siv, cov kev cai ua haujlwm ntawm "Kev Tiv Thaiv Kev Tiv Thaiv Kev Nyab Xeeb rau Cov Cuab Yeej Hluav Taws Xob" yuav tsum ua raws.
b.Txuas lub transmitter X thiab transmitter Y rau cov insulating rods feem (qhov ntev ntawm cov insulating rods nyob ntawm qhov voltage)
c.Qhib lub hwj chim hloov ntawm lub receiver, thiab lub receiver yuav cia li taug qab thiab tso saib lub waveform curves ntawm X thiab Y theem.Muab cov theem sib txawv ntawm X thiab Y theem.(≤ ± 20 degrees yog nyob rau hauv-theem,> 20 degrees yog tawm-ntawm-theem) thiab qhia nyob rau hauv-theem lossis tawm-ntawm-theem.
Cov kev ceev faj
1. Kev ua haujlwm nyob rau hauv qhov chaw yuav tsum ua raws li cov kev cai ua haujlwm ntawm "Power Safety Tool Pre-Test Regulations"
2. Tsis txhob siv xov tooj cua transmitters (walkie-talkies, thiab lwm yam) tib lub sijhawm thaum siv, kom tsis txhob cuam tshuam nrog lub receiver.