Nyob rau nruab nrab Lub Peb Hlis, ib tus neeg siv khoom hauv Beijing tau hu rau peb lub tuam txhab hauv xov tooj los nug txog tus nqi ntawm "transformer bushing localized on-line monitoring system".Tom qab kev sib txuas lus ntawm tus thawj tswj hwm hauv cheeb tsam thiab tus thawj kws tshaj lij engineer thiab cov neeg siv khoom, tag nrho cov khoom tsim nyog thiab cov khoom tsim nyog tau txiav txim siab hauv 2 hnub, thiab ob tog thaum kawg tau kos npe rau daim ntawv cog lus rau kev koom tes.
HV Hipot GDPD-BR-OL Transformer Bushing PD Online Monitoring System
Lub transformer PD on-line xyuas system yog tsim rau on-line thiab off-line saib xyuas ntawm ib feem tawm ntawm transformer bushings nrog voltage theem ntawm 110kV thiab saum toj no.Lub transformer bushing ib feem tso tawm hauv online xyuas qhov system tsim los ntawm kev sib txuas cov teeb liab ua cov thev naus laus zis thiab cov cuab yeej siv tshuab virtual yog siv rau kev tshuaj xyuas ntawm transformer bushings ntawm 110KV thiab saum toj no, thiab tuaj yeem khaws cov kev ntsuam xyuas ntawm txhua theem transformer bushing thiab ua kev tsom xam, yog li. kom raws sij hawm Nrhiav kom paub cov rwb thaiv tsev tsis xws luag ntawm lub transformer bushing, thiab muab cov txheej txheem rau kev ntsuam xyuas cov rwb thaiv tsev theem thiab aging degree, thiab muab lub hauv paus rau kev saib xyuas ntawm lub transformer.
Qhov tsawg kawg nkaus ntsuas qhov paug tawm ntawm qhov system no: 20mV (ntawm qhov chaw), qhov ntau zaus yog 200kHz ~ 300MHz, lub sijhawm daws teeb meem ntawm cov pa tawm yog 10μs, thiab theem kev daws teeb meem yog 0.18 °.
Lub kaw lus muab 50 lub hwj chim zaus lub voj voog tawm daim duab, ob-dimensional (q-φ, N-φ, Nq), peb-dimensional (Nq-φ) spectrum, uas tuaj yeem siv los txheeb xyuas hom paug.
Cov ntaub ntawv tsim los ntawm MySQL tuaj yeem sau cov ntsuas theem ib ntus, tso tawm tus nqi, tawm theem, ntsuas lub sijhawm thiab lwm yam tsis muaj feem cuam tshuam.
Raws li cov khoom siv tsis xws li transformer bushing qauv, ntsuas qhov chaw, thiab lwm yam., nws tuaj yeem muab cov kab hluav taws xob tawm thiab muaj kev ceeb toom ntxov thiab lub tswb ua haujlwm, thiab tuaj yeem nug, tshem tawm, thiab thaub qab cov ntaub ntawv.
Lub kaw lus tau txais kev tiv thaiv kev cuam tshuam zoo xws li kev lim dej digital thiab teeb tsa qhov chaw pib, thiab cov ntaub ntawv xeem yog qhov tseeb thiab ntseeg tau.
Cov neeg siv khoom txaus siab yog peb lub zog tsav!Nyob rau hauv lub neej yav tom ntej, HV Hipot yuav tsis hnov qab nws lub hom phiaj qub, ua ntej, thiab ua haujlwm nrog cov neeg siv khoom tshiab thiab qub los muab cov khoom siv zoo dua thiab cov kev pabcuam zoo rau lub zog hluav taws xob thiab pab lub zog ua haujlwm zoo.
Post lub sij hawm: Mar-24-2022