GDWS-311RC SF6 Gas Dew Point Tester
GDWS-311RC yog cov cuab yeej zoo tshaj plaws los ntsuas cov dej ntws ntawm SF6 roj.Cov ntsiab lus tseem ceeb yog DRYCAP series sensors tsim los ntawm Finland Vaisala tuam txhab.Nrog rau kev kho vajtse chips thiab software zoo heev algorithms ntawm STMicroelectronics, peb tau tsim ib tug tshiab tiam ntawm roj ya raws ntsuas ntsuas.
●Kev saib xyuas dej noo ntawm SF6 cov khoom siv roj hluav taws xob rau hluav taws xob hluav taws xob
●SF6 Gas Lub tog raj kheej Gas zoo kuaj
●High purity gas manufacturing
●Semiconductor kev lag luam qhuav roj muab
●Kev tshawb nrhiav thiab kev tsim kho siv
●Chav tsev huv si/qhuav tsev saib xyuas
●Hlau kho cua sov chaw thiab chaw kuaj muaj roj av noo, xws li cua, CO2, N2, H2, O2, SF6, Nws, Ar thiab lwm yam inert gases.
●Zoo dua ± 2 ℃ ntsuas qhov tseeb.
●Tag nrho cov roj txoj kev yog cov khoom siv polymer tsim, ua kom tsis muaj qhov tshwm sim ntawm phab ntsa dai thiab lav qhov kev ntsuas ceev.
●Cov roj-dawb stainless hlau lub cev tswj valve yog siv los xyuas kom meej qhov tseeb ntawm qhov ntsuas tus nqi.
●Advanced software algorithms txhim kho qhov ntsuas qhov tseeb ntawm sensors.
●Combined chassis configuration tov, cov neeg siv tau yooj yim sib txuas cov cuab yeej thiab accessories.Lub pob tag nrho yog nqa, uas ua rau cov neeg siv muaj kev paub ntau dua.
●Pib mus kuaj, tsis tas yuav preheat thiab oscillate.
●Kub conversion thiab siab cov ntaub ntawv kho.
●Fuzzy xam tshuab.
●High-power lithium roj teeb lub zog, paub AC thiab DC dual fais fab mov.Tsis tas yuav tsum muaj lub zog AC ntawm qhov chaw.Lithium roj teeb fais fab mov txuas ntxiv ua haujlwm rau ntau tshaj 8 teev yam tsis tas yuav muaj lub zog hluav taws xob sab nraud.
●Anti-electromagnetic cuam tshuam Circuit Court tsim kom ntseeg tau cov khoom lag luam.
●Gas recycling muaj nuj nqi, ib puag ncig-phooj ywg.
●Cov ntaub ntawv xeem yog ruaj khov thiab tuaj yeem muab ob qho tib si dew point qhov tseem ceeb thiab hloov pauv dew point qhov tseem ceeb ntawm 20 ℃.
●Qhov zoo tshaj plaws kev xeem khiav cheeb tsam qhia tau hais tias tus neeg siv yuav kho cov pa roj intuitively thiab sai.Txo lub sij hawm xeem.
●Cov cua nkag yog tsim los nrog ib qho me me ntawm nws tus kheej-sealing sib koom ua ke, thiab cov huab cua txoj kev yuav tsum tau kuaj yuav tsis xau thaum txoj kev huab cua raug txiav.
●Txoj kev ntsuas: Resistive thiab Capacitive ntsuas txoj cai
●Kev ntsuas ntau: dew point -80 ℃ --- + 20 ℃ (kev txhawb nqa ppmv)
●Qhov tseeb: ± 2 ℃
(thaum lub dew taw tes kub qis dua 0 ℃, qhov tso zis sensor yog qhov taw tes khov)
●Lub sij hawm teb: 63% [90%]
+20 → -20 ℃ Td 5s [45s]
-20 → -60 ℃ Td 10s [240s]
●Kev daws teeb meem: 0.01 ℃
●Rov ua dua-muaj peev xwm: ± 0.5 ℃
●Chav tsev: ℃, ppm, ℃ P20 (hloov tus nqi ntawm 20 ℃)
●Gas ntws: 400-600ml / min
●Flow zaub: 0-1000mL digital flow meter
●Qauv roj siab: ≤1MPa
●Fais fab mov: 220VAC ± 10%, 50Hz, AC / DC siv, kev ua haujlwm tsis tu ncua tsis pub tsawg dua 8 teev.
●Siv ib puag ncig kub: -20-- + 60 ℃
●Ib puag ncig cov av noo: 90% RH
●Kev ntsuas tus nqi cuam tshuam: Tsis muaj kev cuam tshuam ntawm lub siab thiab ntws
●Loj: 395 * 295 * 155mm
●Luj: txog 2 kg
Lub ntsiab unit | 1 qob |
Adapter | 1 teeb |
Teflon yeeb nkab (xws li ntws hloov valve thiab ceev connector) | 1 teeb |
Lub cev | 1 teeb |
Cov khoom seem | 1 teeb |
Charger | 1 qob |
Cov neeg siv's Qhia | 1 luam |
Test Report | 1 luam |