GDJB-1200A Rau Phase Relay Protection Test Set
●Cov zis tawm mus txog 6-theem voltage 6-theem tam sim no, uas tuaj yeem ua ke kom paub cov pa 4-theem voltage 3-theem tam sim no hom, 6-theem voltage hom, 6-theem tam sim no hom, thiab 12-theem tso zis hom.
●High-performance embedded industrial tswj computer thiab 8.4-nti loj-screen high-resolution xim TFT kua siv lead ua zaub, uas muaj peev xwm muab cov ntaub ntawv nplua nuj thiab intuitive, nrog rau cov xwm txheej tam sim no ntawm cov cuab yeej ua haujlwm, cov lus qhia ua haujlwm tom ntej thiab ntau yam ntaub ntawv pab;
●Cov zis siv lub siab-fidelity, high-reliability modular linear power amplifier es tsis txhob ntawm ib tug hloov hom hwj chim amplifier rau superior kev kawm.Nws yuav tsis tsim kom muaj kev cuam tshuam loj thiab nruab nrab ntawm qhov chaw sim, thiab nws yuav ua kom muaj kev sib tw zoo heev thiab qhov tseeb ntawm qhov siab tam sim no mus rau qhov tam sim no me me.
●Cov khoom tso tawm yog tswj los ntawm DSP, uas muaj kev suav ceev ceev, muaj zog ntawm lub sijhawm ua haujlwm digital teeb liab muaj peev xwm, kis tau tus mob bandwidth thiab high-resolution D / A hloov dua siab tshiab.Cov zis waveform muaj siab precision, me me distortion thiab zoo linearity.Nws tau txais ntau cov thev naus laus zis siab heev thiab cov khoom siv sib xyaw ua ke, thiab tau ua tiav kev tsim qauv tsim.Yog li ntawd, cov cuab yeej yog me me, lub teeb nyob rau hauv qhov hnyav, tag nrho ntawm kev ua haujlwm, nqa tau yooj yim, thiab tuaj yeem ua haujlwm ib zaug pib, thiab qhov kev sim no yooj yim heev.
●Nws tuaj yeem ua tiav ntau qhov kev txheeb xyuas qhov loj loj nrog kev ua haujlwm siab ntawm automation.Nws tuaj yeem kuaj tau yooj yim thiab luam theej duab ntau qhov chaw tiv thaiv, ua qhov ua yuam kev, khaws cov ntaub ntawv sim hauv lub sijhawm, tso saib cov duab vector, thiab luam tawm cov ntaub ntawv hauv online.
●Muaj kev ywj pheej 110V thiab 220V nplooj siab kho tau DC fais fab tso zis rau kev tshuaj xyuas ntawm qhov chaw.
●Lub cim tshiab GDJB-1200A tester yog nruab nrog 10-txoj kev qhib thiab 8-txoj kev qhib, uas yooj yim rau kev txhaj tshuaj rau tus kheej.Kev sib tiv tauj yog sib xws nrog qhov khoob khoob thiab 0 ~ 250V cov neeg muaj peev xwm, uas tuaj yeem ua tau ntse thiab paub txog.
●Muaj peev xwm ua tau ntau yam kev ua haujlwm calibration nyuaj, thiab tuaj yeem kuaj tau yooj yim thiab luam theej duab ntau qhov chaw tiv thaiv kev ua txhaum.Khaws cov ntaub ntawv xeem hauv lub sijhawm, tso saib cov duab vector, luam ntawv, thiab lwm yam.
●Lub tshav kub dissipation qauv yog tsim tsim nyog, cov cuab yeej tiv thaiv kev ntsuas yog txhim khu kev qha thiab zoo meej, thiab lub hwj chim soft start function, software self-diagnosis thiab output blocking muaj nuj nqi.
AC tam sim no tso zis | 6-theem (RMS) | 6 * 0 ~ 30A |
3-theem (RMS) | 3 * 0 ~ 60A | |
6-phase parallel tam sim no tso zis (RMS) | 0 ~ 180A | |
Tso cai ntev ua haujlwm tus nqi ntawm theem tam sim no (RMS) | 10 A | |
Maximum tso zis zog ntawm theem tam sim no | 400 VA | |
Tso cai sijhawm ua haujlwm @ max.tso zis ntawm 6-theem parallel tam sim no | 10s ib | |
Qhov tseeb | 0.5A ± 2mA >0.5A 0.2% | |
Ntau zaus (Fundamental wave) | 0 ~ 1000Hz | |
Harmonic sij hawm | 0 ~ 20 x | |
DC tam sim no tso zis | Cov zis tam sim no | 0 ~ ± 10A / theem;0 ~ ± 60A / 6-pahse parallel |
Qhov tseeb | 0.5% | |
Maximum tso zis load voltage | 20V | |
AC Voltage tso zis | Phase voltage tso zis (RMS) | 0 ~ 120V Qhov tseeb: 0.2% |
Kab hluav taws xob tso zis (RMS) | 0 ~ 240V | |
Phase voltage / Kab voltage tso zis zog | 80VA / 100VA | |
Ntau zaus (Fundamental wave) | 0 ~ 1000Hz | |
Harmonic sij hawm | 1 ~ 20 lub sijhawm | |
DC Voltage tso zis | Phase voltage tso zis amplitude | 0 ~ ± 160V Qhov tseeb: 0.5% |
Kab voltage tso zis amplitude | 0 ~ ± 320V | |
Phase voltage / Kab voltage tso zis zog | 70VA / 140VA | |
Binary | Binary tswv yim | 10 channels |
Idle contact | 1 ~ 20mA, 24V | |
Muaj peev xwm tiv tauj tau | "0": 0 ~ + 6V;"1": +11 V ~ + 250 V | |
Binary tso zis | 8 khub DC: 220V / 0.2A;Lub hwj chim: 220V / 0.5A | |
Lub Sijhawm Ntsuas Ntau Yam | 0.1ms ~ 9999s Kev ntsuas qhov tseeb: <0.1mS | |
Dimension & Nyhav | 480 * 360 * 200mm³ 19kg |
Tsis muaj. | Lub npe | Kev piav qhia | Qty/Unit | Duab |
1 | Chav tsev loj | GDJB-1200A | 1set ib |
|
2 | Fuse | 2A | 4daim |
|
10 A | 4daim | |||
3 | Fais fab qaum |
| 1 qob |
|
4 | Test hlau | 0.5m (liab, daj, ntsuab, dub txhua 2 daim) | 8 qab |
|
5 | Test hlau 4 core | Dub(liab, daj, ntsuab, dub)- tiaj | 2 qab |
|
6 | Test hlau 4 core | Dub(liab, daj, ntsuab, dub)- ncig | 2 qab |
|
7 | Test hlau | xiav | 1 qob |
|
8 | Test hlau | (dawb, kas fes txhua 1 daim) | 2 qab | |
9 | Test hlau | liab, ntsuab, daj txhua 1 daim) | 3 qab | |
10 | Test hlau | dub | 2 qab | |
11 | Kev sib txuas lushlau |
| 1 qob |
|
14 | Loj xeem clamp | (liab, daj, ntsuab, dub txhua 1 daim) | 4 qab |
|
15 | Me me xeem clamp | (daj, ntsuab, txhua 4 daim) | 8 qab | |
16 | Me me xeem clamp | (liab, dub txhua 5 daim) | 10 daim | |
17 | Piv txwv | (liab, daj, ntsuab, dub txhua 2 daim) | 8 qab | |
18 | Xeem koob | (liab, daj, ntsuab, dub txhua 3 daim) | 12 qab | |
19 | CD |
| 1 luam |
|
20 | QC dhau | Hauv Lus Askiv | 1 luam |
|
21 | Phau ntawv | Hauv Lus Askiv | 1 luam |