GDFJ-311M SF6 Gas Decomposition Khoom Tester
GDFJ-311M SF6 Gas Decomposition Product Tester yog ib qho khoom siv nqa tau tsim los ntsuas SF6 roj decomposition khoom.Lub ntsiab tivthaiv nrog electrochemical sensor los ntawm Membrapor los kuaj SF6 roj decomposition khoom.Tsis tas li ntawd, peb kuj tau txais kev tshaj lij kho vajtse chips thiab software zoo heev algorithms ntawm STMicroelectronics.
Decomposition khoom tsom xam ntawm SF6 roj insulated cov khoom siv hluav taws xob
Kev tshawb pom zoo ntawm SF6 roj rov siv dua
Kev siv R & D
DL/T 639-1997: Kev Nyab Xeeb thiab Kev Tiv Thaiv Phau Ntawv Qhia rau Kev Ua Haujlwm Kev Xeem thiab Kev Saib Xyuas Cov Neeg Ua Haujlwm ntawm SF6 Cov Khoom Siv Hluav Taws Xob.
Guodian No.72 Annex 3 [1999] Kev Ntsuas Kev Tswj Xyuas Zoo thiab Kev Tswj Xyuas Cov Hluav Taws Xob Hluav Taws Xob Hluav Taws Xob.
GB/T 17626: Electro-magnetic Compatibility - Kev Ntsuas thiab Kev Ntsuas.
GB/T 2423: Kev Ntsuas Ib puag ncig ntawm cov khoom siv hluav taws xob thiab hluav taws xob.
DL/T596: Kev Tiv Thaiv Kev Ntsuas Cov Khoom Siv Hluav Taws Xob.
GB/T 6388: Thauj Pob Shipping Mark.
GB/T 18867-2014: Gases for Electronic Industry - Sulphur Hexaflouride.
GB/T8905: Phau ntawv qhia rau kev tswj thiab ntsuas SF6 Gas hauv cov khoom siv hluav taws xob.
Txoj kev ntsuas | Electrochemical ntsuas txoj cai (nrog sensor los ntawm Membrapor) |
Ambient kub | -20 ℃ ~ + 60 ℃ |
Kev ntsuas ntau | SO2: 0 ~ 200PPmv, H2S: 0 ~ 200PPmv CO: 0 ~ 500PPmv, HF: 0 ~ 50PPmv |
yuam kev | SO2: <10PPmv, ± 0.3PPmv;> 10PPmv, ± 3% H2S: <10PPmv, ± 0.3PPmv;> 10PPmv, ± 3% CO: <50PPmv, ± 2PPmv;> 50PPmv, ± 4% HF: <10PPmv, ± 0.3PPmv;> 10PPmv, ± 3% |
Rov ua dua-muaj peev xwm | SO2: <10PPmv, ± 0.2PPmv;> 10PPmv, ± 2% H2S: <10PPmv, ± 0.2PPmv;> 10PPmv, ± 2% CO: <50PPmv, ± 2PPmv;> 50PPmv, ± 2% HF: <10PPmv, ± 0.2PPmv;> 10PPmv, ± 2% |
Kev daws teeb meem | 0.1 pwm |
Display unit | PPmv |
Gas ntws | 200 ~ 300ml / min |
Gas flow zaub | 0 ~ 1000mL imported digital gas flow meter |
Gas siab | ≤1MPa |
Cov av noo | 90% RH |
Kev ntsuas tus nqi cuam tshuam | Tsis muaj kev cuam tshuam ntawm lub siab thiab ntws |
Fais fab mov | 220VAC ± 10%, 50Hz, AC / DC siv, ua haujlwm tsis tu ncua yog ntau tshaj 8 teev. |
Loj | 395 * 295 * 155mm |
Qhov hnyav | 2kg ua |
Lub ntsiab unit | 1set ib |
Teflon yeeb nkab (xws li ntws hloov valve thiab ceev connector) | 1set ib |
Gas kav | 1set ib |
Khoom seem | 1set ib |
Cov neeg siv phau ntawv qhia | 1 luam |
Warranty card | 1 luam |
Factory test report | 1 luam |
Charger | 1pc ua |