GDBT-8610P Roj teeb Impedance Tester
GDBT-8610P Roj Teeb Tester yog dav siv hauv cov chaw hauv qab no:
●Telecom: Chaw Ua Haujlwm Hauv Nruab Nrab, cov chaw ua haujlwm cov ntaub ntawv thiab cov chaw nyob deb
● Kev Siv Hluav Taws Xob: Switchgear, Chaw nres tsheb fais fab thiab chaw tsim hluav taws xob
● Cov Tsev Kawm Ntawv Nyiaj Txiag: Corporate Data Centers
● Petrochemical: Txheej Txheem Tswjhwm
● Offshore platforms
● Tsoom fwv: Hauv zos thiab cheeb tsam
● Cov Chaw Ua Se thiab Cov Nyiaj Tau Los
● Kev Ruaj Ntseg Hauv Tebchaws, Tsev Kawm Ntawv, Tub Rog thiab Navy
● Cov Cuab Yeej Cuab Yeej, Hluav Taws Xob thiab Tub Ceev Xwm
● Tsev Kho Mob UPS system
● Cov khoom siv hluav taws xob
● SLA roj teeb tsim khoom
● Kev ntsuas dav dav: 5 ~ 6000Ah, sib xws rau ib leeg ntawm 1.2V, 2V, 6V thiab 12V
● Smart thiab portable handheld ntaus ntawv, rugged thiab yooj yim mus-mus
● Xim kov npo nrog kev xaiv ua haujlwm ntawm cov keyboard
● Ib txhij sim rau qhov voltage, tsis kam thiab kwv yees lub peev xwm ntawm cov roj teeb
● Kev ntsuas online, tsis tas yuav tshem lub roj teeb thiab hlua ntawm nws lub cev rau kev sim, muaj kev nyab xeeb thiab yooj yim
● Kev sim ceev ceev rau roj teeb thiab hlua hauv vib nas this nrog kev sim cov ntaub ntawv nws pib txuag
● Muaj zog tiv thaiv kev cuam tshuam nyob rau hauv siab tam sim no nrog kev ruaj khov thiab ua tau zoo
●Testing zaus qis dua 10 Hz, zoo kom tsis txhob cuam tshuam los ntawm kev ua haujlwm ntawm lub roj teeb nws tus kheej
●Drect USB tsav rau software hloov tshiab thiab cov ntaub ntawv hloov mus rau PC rau kev tshuaj xyuas ntxiv
●Powerful PC tswj software, yooj yim rau cov ntaub ntawv khaws cia thiab tshuaj xyuas
● Lub cim xeeb loj rau kev sim cov ntaub ntawv khaws cia ntau dua 3000 lub hlwb
●Buzzer Tswb muaj nuj nqi thiab tiv thaiv dhau voltage, ruaj ntseg siv
● Auto-calibration muaj nuj nqi ua ntej kev sim, txhim kho qhov kev xeem raug
●Retest thiab them nyiaj ua haujlwm: ib qho kev ua haujlwm tsis raug lossis tsis ua haujlwm tuaj yeem rov sim dua nrog ib nyem
●Referenced cov ntaub ntawv nyob rau hauv lub cim xeeb rau kev sib piv ntawm koj qhov kev xeem, thiab tus kheej-txhais siv tus nqi muaj nyob
Kev tiv thaiv kab mob | 0.00mΩ ~ 100mΩ | Voltage ntau | 0.000V ~ 16V * |
Min xeem daws teeb meem- hluav taws xob - tsis kam
| 1mv ua 0-999μΩ: 1 μΩ 1-9mΩ: 10μΩ (0.01mΩ) 10-99mΩ: 100μΩ (0.1mΩ) | Ntsuas qhov tseeb -voltage - tsis kam
| ± 0.2% rdg ± 6dgt 0μΩ-250μΩ: 8% ± 6DGT 250μΩ-500μΩ: 3% ± 6DGT 500μΩ-100mΩ: 1% ± 6DGT |
Fais fab mov | 7.2V 2400 mAhLi-ion roj teeb | Lub sijhawm ua haujlwm | Ntau tshaj 5 teev tom qab them tag nrho |
Ntsuas cov ntaub ntawv nco | 3000 cev | Kev ua haujlwm ib puag ncig | 0 ℃ to 40 ℃90% RH |
LCD zaub | 320 * 240 pixel TFT kov npo | Dimension(lub ntsiab unit) | L210 * W110 * H60 hli |
Net nyhav(pob) | 2 kg ib | Chaw nres nkoj | Mini USB |