GD6900 Capacitance thiab Dissipation Factor Tester
GD6900 ntsuas qhov capacitance thiab dielectric poob yam tseem ceeb (tgδ) ntawm cov khoom siv hluav taws xob siab.Nws yog integrated qauv, built-in dielectric poob xeem choj, sib txawv zaus adjustable fais fab mov, boosting transformer thiab SF6 txheem capacitor.
Cov khoom siv hluav taws xob siab yog tsim los ntawm cov khoom siv hluav taws xob sab hauv, uas yog siv los ntsuas cov khoom ntsuas tom qab kev hloov pauv.Yog tias ntxiv lub khob rwb thaiv tsev thiab cov cuab yeej tswj qhov kub thiab txias, dielectric poob ntawm cov roj insulating tuaj yeem kuaj tau.
●Kov LCD npo zaub.
●Rwb thaiv tsev tiv thaiv kev ntsuas: Ua-nyob rau hauv rwb thaiv tsev tiv thaiv kev ntsuas module, tuaj yeem nqa tawm Rwb thaiv tsev tsis kam (IR), nqus piv (DAR), polarization Performance index (PI) kuaj.
●Daim ntawv qhia hnub nti thiab loj cia hauv.Txuag cov txiaj ntsig kev xeem raws li lub sijhawm txiav txim, tshawb xyuas cov ntaub ntawv keeb kwm thiab luam tawm qhov tshwm sim.
●Cov ntaub ntawv ntsuas tuaj yeem raug xa tawm los ntawm U disk.
●Ntau hom kev sim, nrog rau cov qauv hauv high voltage, sab nraud high voltage, sab hauv tus qauv, lwm tus qauv, GST / UST, nws tus kheej excitation.Kev ntsuas hluav taws xob siab (ntau tshaj 10kV) dielectric poob tuaj yeem ua rau hauv qhov xwm txheej ntawm tus qauv sab nraud sab nraud siab voltage.
●Kuaj tag nrho kaw CVT (Capacitive Voltage Transformer) C1 thiab C2 dielectric poob thiab capacitance tib lub sijhawm.Kuj sim CVT transformation piv thiab voltage lub kaum sab xis sib txawv.
●Lub dielectric poob thiab capacitance tus nqi ntawm C0 nyob rau hauv lub Upper kawg ntawm CVT tuaj yeem ntsuas los ntawm kev siv txoj kev thim rov qab.
●High ceev sampling teeb liab.Inverter thiab sampling Circuit Court hauv yog digitized tswj.Cov zis hluav taws xob tau hloov kho tas li.
●LCR tsis siv neeg ntsuas.Inductance, capacitance, tsis kam, lub kaum sab xis tuaj yeem ntsuas thiab pom.
●Kev tiv thaiv ntau yam ntawm input voltage fluctuation, tso zis luv luv Circuit Court, tshaj-voltage, tshaj tam sim no, kub, ruaj ntseg thiab txhim khu kev qha.Lub caij no, nws muaj kev ua haujlwm ntawm kev sim hauv av, qhov kev txhawb zog tsis raug tso cai rau cov khoom siv tsis yog hauv av.
●Tsis tas yuav dismantle HV ua rau ntsuas dielectric poob thiab capacitance ntawm CVT.
●Zaus tuaj yeem hloov mus rau 50Hz, 47.5Hz / 52.5Hz, 45Hz / 55Hz, 60Hz, 57.5Hz / 62.5Hz, 55Hz / 65Hz.
| Kev ua haujlwm | -15 ℃ ~ 40 ℃ | RH <80% | ||||||
| Anti-interference txoj cai | Kev hloov pauv zaus | |||||||
| Fais fab mov | AC 220V ± 10%, 50 / 60Hz | Generator tuaj yeem siv tau. | ||||||
| High voltage tso zis | AC 0.5KV ~ 10KV (12kV yeem) | 0.1kV ib | ||||||
| Qhov tseeb | 2% | |||||||
| Max.tam sim no | 200 mA | |||||||
| Muaj peev xwm | 2000 VA | |||||||
| Self-excitation zog | AC 0V ~ 50V / 15A | 50Hz, 60Hz ib zaus 45HZ / 55HZ 47.5HZ / 52.5HZ 55HZ / 65HZ 57.5HZ / 62.5HZ Tsis siv neeg dual zaus | ||||||
| Kev daws teeb meem | tus nqi: 0.001% | Cx: 0,001 pf | ||||||
| Qhov tseeb | ∆tgδ: ± (nyeem * 1.0% + 0.040%) | |||||||
| ∆C x: ± (nyeem * 1.0% + 1.00PF) | ||||||||
| Kev ntsuas ntau | tg dab | Tsis txwv | ||||||
| C x | 15pF < Cx < 300nF | |||||||
| 10 KV | Cx < 60 nF | |||||||
| 5 kvu | Cx <150 nF | |||||||
| 1 KV | Cx <300 nF | |||||||
| CVT test | Cx <300 nF | |||||||
| LCR ntsuas ntau yam | L> 20H (2kV) | R> 10KΩ (2kV) | ||||||
| LCR ntsuas qhov tseeb | 0.1% | Kev daws teeb meem | 0.01 ib | |||||
| CVT ratio ntau | 10-10000 | |||||||
| CVT ratio qhov tseeb | 0.1% | |||||||
| CVT ratio daws teeb meem | 0.01 ib | |||||||
| Rwb thaiv tsev tsis kam | DC siab voltage | 5 ~ 10kV | Qhov tseeb | ± (2% * Nyeem ntawv + 10V) | ||||
| IR qhov tseeb | 100kΩ-1000GΩ: <5% (kuaj voltage tsis tsawg dua 250V) 100GΩ-1000GΩ: 10% (kuaj voltage tsis tsawg dua 10000V) | |||||||
| Dimension | Loj: 350 (L) × 270 (W) × 270 (H) | |||||||
| Lub thawv khoom siv: 350 (L) × 270 (W) × 160 (H) | ||||||||
| Lub peev xwm nco | 200 pawg, USB flash disk cia yog txaus siab. | |||||||
| Qhov hnyav | Qhov hnyav: 22.75Kg | |||||||
| Accessory box: 5.25Kg | ||||||||
| Tester | 1set ib |
| Accessories Case | 1 qob |
| HV liab test lead 8m | 1 qob |
| LV dub test lead 8m | 1 qob |
| Fais fab Qaum 1.8m | 1 qob |
| CVT txuas lead 5m | 1 qob |
| Pem hauv ntej 2m | 1 qob |
| Luam ntawv | 2 yob |
| 10A fuse | 3 qab |
| Tus neeg siv phau ntawv qhia | 1 luam |
| Factory Test Report | 1 luam |
| Xaiv tau accessories | |
| Roj Test Cell | 1pc ib |
| Cua sov tswj | 1pc ib |
Nrog cov roj ntsuas ntawm tes thiab lub tshuab cua sov, cov neeg siv tuaj yeem kuaj tan delta ntawm dielectric kua xws li roj transformer.
Cua sov tswj
Roj nkoj