GDSL-A Tsis Siv Neeg 3-theem Thawj Qhov Kev Txhaj Tshuaj Tam Sim No Teeb nrog Kev Ntsuas Kub

GDSL-A Tsis Siv Neeg 3-theem Thawj Qhov Kev Txhaj Tshuaj Tam Sim No Teeb nrog Kev Ntsuas Kub

Cov lus piav qhia luv luv:

GDSL-A Series 3-theem Primary Tam sim no Txhaj Tshuaj Test Teeb nrog Kev Ntsuas Kub yog cov cuab yeej zoo tshaj plaws rau kev ntsuas cov cuab yeej siv hluav taws xob tam sim no hauv kev lag luam hluav taws xob thiab hluav taws xob, siv hauv cov chaw tsim hluav taws xob, chaw faib hluav taws xob, hluav taws xob tsim hluav taws xob thiab cov chaw tshawb fawb, nrog rau cov yam ntxwv. ntawm me me, lub teeb yuag, yooj yim siv thiab txij nkawm.

 

 

 

 


Product Detail

Khoom cim npe

GDSL-A 3-phase Primary Current Injection Test Set with Temperature Test
Muaj nuj nqi

Nws muaj xoom kev tiv thaiv muaj nuj nqi los tiv thaiv qhov cuam tshuam ntawm cov tam sim no loj los ntawm kev puas tsuaj rau cov qauv.Nws tsis tuaj yeem pib thaum nws tsis nyob ntawm xoom txoj haujlwm.
Kev xaiv cuam tshuam muaj nuj nqi, thaum qhov kev ntsuas hluav taws xob nrawm nrawm ua tiav, qhov kev tiv thaiv xoom tuaj yeem raug txiav tawm thiab qhov xav tau tam sim no tus nqi tuaj yeem ncaj qha tawm.
Tso zis tam sim no hom: Qhov tseeb RMS tus nqi yog hloov kho tsis tu ncua.
Cov zis tam sim no yog tus qauv sine yoj, thiab tus waveform distortion tus nqi tsawg dua 5%.
Voltage thiab tam sim no zaub txais yuav tshiab high-precision LED cov zaub
Hloov tau qhov loj me tam sim no los txhim kho cov duab zoo rau kev nyeem ntawv ntau dua.
Lub hwj chim mov voltage thiab regulator tso zis voltage yuav hloov mus tso saib kom yooj yim saib.
Cov cuab yeej muaj peev xwm tsim tau rau lub sijhawm luv luv, ua haujlwm tsis sib xws hauv 5 feeb.
Rau kev sim batch, kaw rau 10 feeb tom qab 2.5 feeb ntawm kev ua haujlwm tas mus li.
Nws tuaj yeem ntsuas lub sijhawm ua haujlwm tam sim no ntawm cov khoom siv kuaj thiab sau lub sijhawm xauv lub sijhawm synchronously.(yeem)
Kev ntsuas lub sij hawm ntau: 0.001S ~ 999.999S Kev daws teeb meem 1ms, ntsuas qhov yuam kev: 0.005% ntau yam ± 2digs.(yeem)
Qhov ntsuas tus nqi ntawm thawj qhov tam sim no thiab theem nrab tam sim no tuaj yeem pom ncaj qha los pab txhawb qhov kev ntsuas qhov sib piv ntawm qhov hloov pauv.(yeem)
Secondary tam sim no ntau yam 0 ~ 5A daws teeb meem 1mA (yeem)
Yog tias qhov kub thiab txias (30 feeb - 24 teev) yuav tsum tau kho raws li qhov kub thiab txias ua haujlwm ntev.(yeem)
Tau customized peb-theem nrog qhov sib npaug hloov riser (yeem)
Tau customized AC thiab DC riser (yeem

Specifications

Tawm tswv yim voltage: AC220V / 380V ± 10% 50Hz ± 1.
Cov zis tam sim no:: 0-15000A (raws li cov neeg siv khoom xav tau).
Cov zis hluav taws xob: 6V-24V (raws li cov neeg siv khoom xav tau).
Lub sijhawm ua haujlwm: 8 teev (raws li tus neeg thov kev thov)
ambient kub: -10 ℃ to 50 ℃.
Tam sim no qhov tseeb: ≤ 1.0% (FS).
16-txoj kev ntsuas qhov ntsuas kub.(raws li cov neeg siv khoom xav tau)