GDOH-II Insulating Roj Roj Cov ntsiab lus Tester
GDOH-II Insulating Oil Gas Content Tester yog lub cim tshiab tester txais cov khoom siv siab raug thiab cov cuab yeej tshiab tshaj plaws.Nws yog raws li DL423-91 fais fab kev lag luam tus qauv thiab cov qauv hauv lub tebchaws.Nws yog qhov ua tau zoo dua, ruaj khov thiab txhim khu kev qha hauv kev ua haujlwm, yooj yim rau kev khiav lag luam thiab tsim nyog rau kev txiav txim siab ntawm cov ntsiab lus roj hauv cov khoom siv hluav taws xob ultra-high voltage.Nws yog ib qho khoom siv zoo tshaj plaws rau kev kuaj.
●Cov qauv hlau tag nrho zam cov teeb meem ntawm fragility thiab tsis zoo sealing ntawm cov iav tester.
●Daim ntawv thov ntawm high precision thiab siab stability imported sib txawv siab sensor ua rau cov ntaub ntawv xeem ntau yog thiab repeatable.
●Qhov ntsuas hluav taws xob muaj cov sensors uas ntsuas atmospheric siab thiab ambient kub.Txawm koj nyob qhov twg los xij, koj tuaj yeem ntsuas qhov ntsuas kub thiab huab cua ntawm koj qhov chaw, cia li hloov mus rau cov ntsiab lus roj ntawm 0 ° raws li tus qauv atmospheric siab, thiab tso ncaj qha rau ntawm lub vijtsam LCD.
●Qhov tshwj xeeb ntawm kev txhaj tshuaj tiv thaiv tus qauv tso cai rau koj kom yooj yim xyuas seb lub ntsuas ntsuas puas tau ntsuas lossis ntsuas raug.
●Lub sij hawm ntsuas roj yog luv, thiab tag nrho cov sij hawm sim tsuas siv li 7 feeb xwb.
●Thaum lub sijhawm kuaj, kev ua haujlwm ntawm lub tshuab nqus tsev twj tso kua mis yog tswj los ntawm cov cuab yeej raws li lub xeev, uas txo cov suab nrov thiab ua rau lub neej ntev ntawm lub tshuab nqus tsev twj.
●Lub cuab yeej tuaj yeem khaws cov ntaub ntawv xeem dhau los, thiab khaws lub sijhawm xeem, qhov kub thiab txias, huab cua siab, thiab lwm yam, kom koj tuaj yeem tshawb xyuas cov ntaub ntawv yooj yim.
●Nrog kev ua haujlwm luam ntawv, koj tuaj yeem luam cov ntaub ntawv xeem raws li koj xav tau.
●Tib cov qauv roj tuaj yeem raug xaiv rau cov lej xeem.Tom qab qhov kev xeem tiav lawm, cov txiaj ntsig ib leeg thiab qhov nruab nrab yuav tshwm rau ntawm cov zaub lossis luam tawm.
| High-precision hluav taws xob sib txawv siab sensor | Kev daws teeb meem tsis tsawg dua 0.1%. | |
| Yam tsawg kawg ntawm kev kuaj pom | Tsis ntau tshaj 0.2%. | |
| Qhov tseeb | Qhov txheeb ze yuam kev ntawm qhov rov ntsuas qhov ntsuas yuav tsum tsis txhob tshaj cov nqi hauv qab no: | |
| Gas cov ntsiab lus nyob rau hauv cov roj (Volume feem),% | txheeb ze yuam kev,% | |
| <0.5 | 10 | |
| 0.5 ~ 1.0 | 8 | |
| 1.0 ~ 3.0 | 5 | |
| > 3.0 | 3 | |
| Degassing chav tswj qhov kub thiab txias | 5 ℃ to 70 ℃ saum chav tsev kub | |
| Ua haujlwm fais fab | AC 220V ± 10%, 50Hz | |
| Dimension | 450 * 325 * 350 hli | |
| Qhov hnyav | Txog 20 kg | |
| Tester | 1set ib |
| Fais fab qaum | 1 qob |
| Lub tshuab nqus tsev twj & connector | 1set ib |
| 3mm stainless hlau yeeb nkab | 0.5m, 1.5m |
| Syringe connector | 1set ib |
| Fuse 10A | 3 qab |
| M8 × 1 | 10 daim |
| foob | 10 daim |
| Syringe bracket | 1 qob |
| 1 mL calibration syringe | 1 qob |
| Rotary vane nqus tsev vacuum | 1set ib |
| Phau ntawv qhia | 1 luam |
| Cov khoom pov thawj | 1 luam |
| Factory test report | 1 luam |
| Cov ntawv ntim khoom | 1 luam |