GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer
High voltage Circuit Court breaker yog ib qho tseem ceeb tshaj plaws tswj cov cuab yeej hauv lub zog hluav taws xob.GDKC-12A / B (GDKC-13A) yog siv los kuaj cov yam ntxwv zoo ntawm cov hluav taws xob hluav taws xob hluav taws xob siab.Nws yog ib qho yooj yim rau kev khiav lag luam, nrog cov neeg siab.
●Sijhawm: lub sijhawm qhib / kaw, hauv theem synchronization, theem-rau-theem synchronization ntawm 12 kev sib cuag.
●Kaw resistor: ua ntej hloov lub sij hawm, ua ntej hloov waveform thiab tsis kam ntawm kaw resistor ntawm 6 raws.
●Rov qab qhib: kaw-qhib, qhib-kaw, qhib-kaw-qhib lub sijhawm rau txhua qhov kev sib cuag.
●Bounce: kaw lub sijhawm bounce, sijhawm, txheej txheem thiab waveform ntawm txhua tus neeg sib cuag.
●Velocity: tshaj tawm ntawm kev sib cuag qhib lossis kaw, siab tshaj plaws ceev, lub sij hawm mus txawv tebchaws tus yam ntxwv nkhaus;thawj qhib, thawj kaw thiab thib ob qhib tshaj tawm ntawm kev rov kaw.
●Kev mus ncig: tag nrho kev mus ncig, qhib kev mus ncig, hla kev mus ncig, mus ncig overshoot, bounce amplitude.
●Tam sim no: qhib / kaw tam sim no, tam sim no waveform daim duab ntawm qhib / kaw coil.
●Kev khiav hauj lwm voltage: built-in DC30 ~ 300V / 20A digital, adjustable zog qhov chaw ntawm breaker, cia li ua tiav LV kev xeem ntawm Circuit Court breaker thiab ntsuas qhov voltage tus nqi ntawm Circuit Court breaker.
●IPC rau tus tswv tsev.
●Nws yog qhov tsim nyog los ntsuas cov txheej txheem tsis sib xws ntawm txhua hom SF6 Circuit Court breaker, GIS cov khoom siv hluav taws xob sib txuas, lub tshuab nqus tsev hluav taws xob, roj Circuit Court breaker.
●Muaj zog tiv thaiv kev cuam tshuam.Nws kuj tuaj yeem kuaj tau yooj yim thiab ntsuas qhov tseeb txawm tias interbus nyob hauv 500kV substation.
●Nrog universal velocity sensor (yeem), linear velocity sensor, rotary sensor, yooj yim rau nruab.
●Tsuas yog ib zaug nkaus xwb kom tau txais tag nrho cov ntaub ntawv thiab sib thooj waveform ntawm breaker mechanism xeem.
●Cov ntaub ntawv khaws cia ntawm 1000 pawg, ua-nyob rau hauv lub sijhawm tiag tiag moos, uas yooj yim rau txuag hnub xeem thiab sijhawm.
●LCD npo zaub, nrog qhov sib txawv hloov thiab lub zog-tawm lub cim xeeb.
●Buit-in tshuab luam ntawv, kom tau txais tag nrho cov ntaub ntawv thiab daim duab qhia txhua lub sijhawm sai.
●Nrog lub Circuit Court breaker cov ntaub ntawv tsom xam tswj software.Nws tuaj yeem sib txuas lus nrog PC.Cov txiaj ntsig kev xeem tau ncaj qha khaws cia rau hauv hard disk, thiab tuaj yeem tso tawm rau ntau hom koob, laser lossis inkjet tshuab luam ntawv rau luam ntawv cov ntawv xeem, ua rau kev sim teb rau computerization.
●Siv U disk txuag thiab hloov cov ntaub ntawv ncaj qha.
●Cov kev txheeb xyuas cov software raug muab tso ua ke raws li lub ntsiab lus ntawm kev qhib, kaw nrawm.Nws yog haum rau kev ntsuas ceev rau txhua hom kev hloov.
●Kev siv ib puag ncig
Kev tawm tswv yim: 220V ± 10%, 50Hz ± 10% / GDKC-12B: 230V ± 10%, 60Hz ± 10%
Cua Siab: 86-106kpa
Kub: -10-40 ℃
Humidity: ≤80% RH
●Kev Nyab Xeeb Kev Ua Haujlwm
Rwb thaiv tsev Resistance> 2MΩ
Dielectric zog: Plhaub tuaj yeem tiv taus lub zog zaus voltage 1.5kV ntawm 1 feeb yam tsis muaj flashover thiab arcing.
●Basic Parameters
ib.Sijhawm: Ntau 20000.0ms daws teeb meem 0.01ms
yuam kev 0.1ms ± 1 tus lej hauv 2000ms
1ms ± 1 tus lej hauv 20000ms
GDKC-12B Basic Parameters
ib.Sijhawm: Ntau 20000.0ms daws teeb meem 0.01ms
yuam kev 0.01ms ± 2 tus lej hauv 250ms
0.1ms ± 2 tus lej hauv 2500ms
1ms ± 2 tus lej hauv 20000ms
GDKC-13A Circuit Breaker AnalyzerBasic Parameters
Sijhawm: Ntau 4000.0 + 6000.0 ms daws teeb meem 0.1ms
yuam kev 0.1ms ± 1 tus lej hauv 100ms
0.1% ± 1 tus lej ntau dua 100ms
Tib lub sijhawm
b.Ceev: Ntau yam 20.00m/s daws teeb meem 0.01m/s
Kev ua yuam kev ± 0.1m / s ± 1 tus lej hauv 0-2m / s
± 0.2m / s ± 1 tus lej siab dua 2m / s (± 0.2m / s ± 1 lej ntau dua 100ms)
c.Ncig teb chaws:
| Hom | Ntau yam | Kev daws teeb meem | yuam kev |
| Lub tshuab nqus tsev vacuum | 50.0mm ib | 0.1 hli | 0.1± 1tus lej |
| SF6 Circuit Court breaker | 300.0 hli | 1 hli | |
| RojCircuit Court breaker | 600.0 hli |
d.Tam sim no: ntau yam 20.00A daws teeb meem 0.01A
e.Cov zis hluav taws xob: DC0-300V digital adjustable / 20A (ua haujlwm sai), daws teeb meem 1V.
f.Qhov Loj: 360mm (L) * 280mm (W) * 300mm (H)
g.Qhov hnyav: 10kg (9kg)
h.GDKC-13A Nyhav: 9kg