GDJW-40B Wireless Insulator Tester
GDJW-40B tuaj yeem siv los ntsuas qhov hluav taws xob faib hluav taws xob ntawm cov hluav taws xob raug tshem tawm lossis kev sim kuaj pom ntawm cov hluav taws xob raug tshem tawm, thiab ua kom muaj txiaj ntsig zoo tshawb xyuas qhov teeb meem sab hauv ntawm lub insulator, txhim kho kev khiav hauj lwm kev ntseeg siab ntawm lub hwj chim kab hluav taws xob, thiab txhim kho. kev ua haujlwm zoo ntawm cov neeg ua haujlwm kab uas ua tiav qhov kev sim nyob.Cov khoom no txais kev sib txuas lus wireless, kev sib txuas lus deb ntawm lub tshuab ntes thiab lub davhlau ya nyob twg tuaj yeem ncav cuag 100m saum toj no, Ua kom cov txheej txheem ntsuas muaj kev nyab xeeb thiab txhim khu kev qha, ceev thiab raug.Tsis tas li ntawd, cov cuab yeej muaj qhov muaj zog tiv thaiv kev cuam tshuam, ua raws li (EMC) cov qauv kev cai, hloov mus rau ntau yam kev cuam tshuam ntawm electromagnetic teb.
●Kev khiav hauj lwm voltage: 35-1000KV, sib txawv voltage theem yog siv tau.
●Voltage Measuring range: 0-40kV (tshwj xeeb voltage tuaj yeem kho tau).
●Kev ntsuas yuam kev: ≤ ± 1%.
●Sampling tus nqi: 10 zaug / S.
●Hnub tim teem sij hawm: kho hnub tim thiab lub sij hawm, los pab cov neeg siv los xauj, saib cov ntaub ntawv keeb kwm.
●Kev teeb tsa lub sijhawm rov qab: qhov ci tsis tu ncua, tsis tu ncua, 0-999 feeb tuaj yeem teeb tsa.
●Nws pib lub hwj chim tawm teeb tsa: tsis tau, 0-999 feeb tuaj yeem teeb tsa.
●Qhov kev ncua deb ntawm tes tuav lub davhlau ya nyob twg thiab ntes yog ≤100m.
●Multi-mode tsim, muaj zog applicability, ruaj ntseg thiab yooj yim dua.
●Universal kev sib koom ua ke tsim, pab kom yoog raws cov kev taw qhia ntawm kev ntsuas raws li qhov kev ncua ntawm txoj hlua insulator.
●Ob chav thaiv, muaj zog tiv thaiv kev cuam tshuam, ua raws li EMC cov qauv.
●Cim txiv neej-tshuab interface, yooj yim rau kev khiav lag luam.
| Voltage ntsuas ntau yam | 0-40kV (tshwj xeeb voltage tuaj yeem hloov kho) |
| Kev ntsuas yuam kev | ± 1% |
| Kev daws teeb meem | 0,01kv ua |
| Tus nqi piv txwv | 10sij hawm/S |
| Ua haujlwm tam sim no | ≤120mA(Hand-held davhlau ya nyob twg),≤ 40mA(Ntes) |
| Fais fab mov | 2*1,5v 0AA roj teeb qhuav (Hand-held davhlau ya nyob twg) 2*1,5v 0AAA roj teeb qhuav (Ntes) |
| Lub sijhawm ua haujlwm ruaj khov | ≥12h |
| Kev sib kis nrug | ≥100m (muaj zog txaus) |
| Zaub | LCD zaub, tuaj yeem ua kom pom tseeb hauv qab hnub ci. |
| Ua haujlwm kub | -35 ℃ --- + 60 ℃ |
| Cia kub | -40 ℃ --- + 65 ℃ |
| txheeb ze humidity | ≤90%RH Tsis-condensate |
| Tsis muaj. | Basic configuration | Chav tsev | Qty. | Lus ceeb toom |
| 1 | Handheld lub davhlau ya nyob twg | teeb | 1 | |
| 2 | Dedicated detector | ib daim | 1 | |
| 3 | A,B Ntes | hauv paus | 2 | |
| 4 | AA roj teeb qhuav (1,5v 0) | ntu | 2 | |
| 7 | AAA qhuav roj teeb (1,5v 0) | ntu | 2 | |
| 8 | Ntshuam portable case | ib daim | 1 | |
| 9 | 220kV rwb thaiv tsev pas nrig | hauv paus | 1 | ≤220k uaV match nrog4ntu4M rwb thaiv tsev pas nrig,≥3 30kv phim nrog6 ntu6M insulation pas nrig |
| 10 | Phau ntawv ua haujlwm | luam | 1 | |
| 11 | Daim ntawv xeem | luam | 1 | |
| 12 | Warranty card | luam | 1 | |
| 13 | Cov ntawv ntim khoom | luam | 1 |