GDJB-6000M Smart Substation Relay Protection Test System
GDJB-6000M Smart Substation Relay Protection Test System yog ib tiam tshiab ntawm cov ntse relay tiv thaiv tester tsim raws li "Smart Substation Relay Protection Technical Specifications" thiab "Smart Substation Technical Guidelines".Nws tuaj yeem tsis tsuas yog paub txog kev ua haujlwm tag nrho ntawm cov cuab yeej siv kho qhov muag digital tiv thaiv (IEC61850, ntse digital chaw nres tsheb), tab sis kuj tseem ua tiav kev sim ua haujlwm tag nrho ntawm cov khoom siv tiv thaiv ib txwm muaj (chaw nres tsheb).
GDJB-6000M yog cov khoom siv tshiab txav tau los ntawm nws tus kheej tsim los ntawm kev siv thev naus laus zis xws li kev ua haujlwm ntawm lub sijhawm tiag tiag, cov txheej txheem ua haujlwm siab, thiab cov khoom siv logic loj, ua ke nrog lub zog teb thiab ntau lub zog siv cov kev paub dhau los.Nws yog dav siv rau cov chaw tsim hluav taws xob, cov chaw tsim khoom, cov chaw tsim khoom, cov chaw lag luam thiab cov tsev kawm ntawv, nrog rau lwm lub koom haum tshawb fawb uas yuav tsum tau ua cov kev ntsuas kev tiv thaiv relay lossis tshuaj xyuas.
GDJB-6000M tau txais kev tswj xyuas engineering los tswj qhov kev xeem;kev tswj xyuas qhov project tau txais cov qauv peb-txheej ntawm cov cuab yeej tiv thaiv, hom kev tiv thaiv, thiab qhov ntsuas qhov ntsuas los tswj qhov kev xeem.Cov qauv yog qhov tseeb heev;Nws txhawb nqa analog tso zis, thiab tuaj yeem ua tiav cov zis ntawm cov khoom analog thiab xa & tau txais GOOSE lus;Muab ntau txoj hauv kev los teeb tsa SV thiab GOOSE cov lus, suav nrog kev teeb tsa ntawm phau ntawv, tshawb pom lub network, thiab xa cov ntaub ntawv SCL;Cov xov xwm kho qhov muag muaj qhov hloov pauv tau yooj yim ntawm lub transceiver, uas tuaj yeem xa ntau yam SV thiab GOOSE cov lus nrog 1 qhov chaw nres nkoj kho qhov muag, thiab tib SV thiab GOOSE cov lus tuaj yeem xa los ntawm ntau qhov chaw nres nkoj kho qhov muag.
DL/T 860 Series Standard "Substation Communication Network thiab System"
DL/T 624-2010 "Technical Conditions for Relay Protection Microcomputer Based Test Equipment"
GBT 7261-2008 "Txoj Kev Xeem Txheej Txheem rau Kev Tiv Thaiv Relay thiab Kev Nyab Xeeb Tsis Siv Neeg Cov Khoom Siv"
IEC 60255-24: 2001 "Cov khoom siv hluav taws xob hluav taws xob - Ntu 24: Hom qauv rau kev hloov pauv cov ntaub ntawv hloov pauv (COMTRADE) rau cov tshuab hluav taws xob"
●Smart Test Module
Intelligent test template editing yog txaus siab.Cov khoom xeem tuaj yeem raug muab ntxiv thaum lub sijhawm xeem txheej txheem thiab tau txais kev cawmdim raws li cov ntaub ntawv uas siv tau rov siv tau los txhim kho qhov kev xeem ua haujlwm nyob rau theem kawg ntawm kev tshuaj xyuas thiab tshem tawm. Muaj zog software ua haujlwm.Real-time zaub waveform, max.Peak thiab qhov chaw.Lub software tuaj yeem tshawb xyuas thiab txheeb xyuas qee theem waveform.Windows tuaj yeem zoomed hauv thiab tawm.Ib ntu cov ntaub ntawv tuaj yeem soj ntsuam spectral thiab cov ntsiab lus spectrum ntawm kev tawm waveform tuaj yeem txheeb xyuas.
●Tsis siv neeg kuaj
Nrog rau kev tiv thaiv ntawm qhov chaw thiab kev tiv thaiv digital tsis siv neeg kuaj kev ua haujlwm, tag nrho cov khoom kuaj ntawm ib qho kev tiv thaiv ib leeg tuaj yeem ua tiav nrog ib tus yuam sij.Cov ntaub ntawv xeem thiab cov ntaub ntawv hloov pauv hloov pauv tuaj yeem khaws cia tau txais lossis manually.
●Digital / analog tso zis
Nws tuaj yeem kuaj xyuas qhov sib koom ua ke, kev tiv thaiv, ntsuas thiab tswj cov khoom siv, thiab cov khoom siv ntse ntse ntawm cov chaw nres tsheb digital, thiab tseem tuaj yeem kuaj cov khoom siv xws li kev tiv thaiv analog thiab transformer unit.
●Ib txhij tso zis ntawm analog thiab digital kom muaj nuj nqis
Nws txhawb ib txhij analog tso zis thiab GOOSE lus xa thiab tau txais.
● Ntau hom scanning
Txhawb amplitude, theem, zaus, impedance, vector, sib lawv liag, thiab lub hwj chim yog nqa tawm los ntawm phau ntawv los yog tsis siv neeg xeem, kuj txhawb kev hloov tsis siv neeg kuaj raws li txoj kev gradation, plam thiab synthesis.
● Kev nyab xeeb thiab tswb
Nrog rau cov cua kub thiab kev tiv thaiv tshaj tam sim no, qhov tam sim no muaj qhov qhib-circuit tiv thaiv thiab lub tswb muaj nuj nqi, thiab qhov hluav taws xob qhov hluav taws xob muaj kev tiv thaiv overload thiab luv luv-circuit.
● Virtual Terminal graphical zaub
Txhawb virtual davhlau ya nyob twg graphical zaub muaj nuj nqi, cov ntaub ntawv txaus yog meej.
●Xa thiab txais cov lus tib lub sijhawm
Txhawb IEC61850-9-1, IEC61850-9-2 thiab GOOSE kho qhov muag cov lus tso zis.Lub teeb liab GOOSE tuaj yeem xa thiab tau txais ntawm nws tus kheej, thiab nws tseem tuaj yeem xa thiab txais los ntawm kev sib txuas lus kho qhov muag Ethernet nrog IEC 61850-9-2.
● FT3 / Extended FT3
Txhawb FT3, txuas ntxiv FT3 thiab DL / T 282 cov lus tso tawm, thiab txhawb nqa 2M / 4M / 6M / 8M / 10M baud tus nqi UART encoding thiab 5M / 10M / 20M Manchester encoding.
● Kev kuaj tsis zoo
Nrog kev ua haujlwm tsis zoo ntawm cov lus analog, nws tuaj yeem sim ua qhov txawv txav hauv qhov zoo, xa cov zaus jitter, ncua kev tsis txaus ntseeg, pob ntawv poob, tawm ntawm kauj ruam, tus lej dhia dhia, hom kev saib xyuas, lub xeev virtual hloov thiab lwm yam kev sim.
● Ua txhaum playback
Txhawb kev simulation yuam kev thiab COMTRADE hom ntaub ntawv playback muaj nuj nqi.
● Kev pabcuam MMS
Nrog MMS nyeem ntawv thiab sau ntawv muaj nuj nqi, tuaj yeem nyeem thiab sau cov khoom siv IED ntse thiab lwm yam ntaub ntawv teeb tsa.
● Sijhawm synchronization thiab sijhawm muab sijhawm
Nrog synchronous trigger muaj nuj nqi, kev txhawb nqa ncaj qha nkag mus rau GPS / BD kav hlau txais xov rau lub sijhawm synchronization, kuj txhawb IRIG-B, PPS thiab PTP 1588 lub sij hawm hom thiab tuaj yeem txhawb nqa tawm sab nraud IRIG-B, PPS thiab PTP 1588 lub sijhawm muab teeb liab.
● Hard contact binary input thiab binary output
Cov input kom muaj nuj nqis yog active thiab passive adaptive hu, thiab cov input hom thiab input voltage tau txais kev lees paub.Cov channel raug cais tawm ntawm ib leeg, thiab cov polarity rov qab txuas nrog lub tswb nrov.
●Cov lus tau txais thiab kev tshuaj xyuas
Nrog cov lus tau txais thiab kev tsom xam muaj nuj nqi, cov lus tau txais tuaj yeem qhib nrog ZHNPA rau kev tshuaj xyuas lossis xa tawm.
●Ib hom fiber ntau
Qhov chaw nres nkoj kho qhov muag txhawb nqa ib leeg-fiber kis tau tus mob thiab ib leeg-fiber txais tos thiab txhawb kev ntsuas hluav taws xob kho qhov muag.
●Analog me teeb liab
Nws yog txawm peem rau nrog analog me me teeb liab interface, txhawb 12 txoj kev analog me me teeb liab input, yuav ntsuas -7V ~ 7V AC voltage, txhawb 12 txoj kev analog me me teeb liab tso zis, thiab tso zis -7V ~ 7V AC voltage.
●Kov ua haujlwm
Nruab nrog 10.4 nti high-resolution zaub uas txhawb kev ua haujlwm kov.
●Kev sib txuas wireless
Muab cov kev sim ua tej thaj chaw deb, nrog WiFi module, tus neeg siv-phooj ywg.
| AC voltage qhov tso zis | Ntau yam: 6 × 120V, 120V / 60VA ib txoj kev Qhov tseeb: ± 10mV ntawm 0.2 ~ 2V;± 0.2% ntawm 2V ~ 120V Kev daws teeb meem: 1mV |
| AC tam sim no qhov chaw tso zis | Ntau yam: 6 × 30A, 30A / 150VA ib txoj kev Qhov tseeb: ± 10mA rau 0 ~ 500mA;± 0.2% rau 500mA ~ 30A Kev daws teeb meem: 1mA |
| Cov zis theem | Ntau yam: 0 ~ 360 ° Qhov tseeb: ± 0.1 ° Kev daws teeb meem: 0.1° |
| Tso zis zaus | Ntau yam: 0 ~ 1000Hz Qhov tseeb: ± 0.001Hz (0 ~ 65Hz) ± 0.01Hz (65 ~ 450Hz) ± 0.02 Hz (450 ~ 1000 Hz) Kev daws teeb meem: 0.001 Hz |
| DC voltage qhov tso zis | Ntau yam: 6 txoj kev, txhua txoj kev 0 ~ 130V / 60VA Qhov tseeb: 0.2% |
| DC tam sim no qhov chaw tso zis | Ntau yam: 6 txoj kev, txhua txoj kev 0 ~ 20A / 100VA Qhov tseeb: 0.2% |
| IEC 61850 Kev sib txuas lus interface | Tus naj npawb ntawm cov chaw nres nkoj: 6 khub yog 100M adaptive;2 khub yog 100/1000M adaptive Hom interface: LC Lub wavelength: 1310nm |
| IEC 60044 kev sib txuas lus interface | Tus naj npawb ntawm cov chaw nres nkoj: 6 xa cov chaw nres nkoj, 2 tau txais cov chaw nres nkoj Hom interface: ST Lub wavelength: 850nm |
| Synchronization interface | Ntim: 1 * GPS / BD ANT;2 * IRIG-B / PPS kho qhov muag teeb liab-1 rau lub sijhawm, 1 rau lub sijhawm muab;2 khub * IRIG-B / PPS hluav taws xob teeb liab-1 khub ntawm lub sijhawm, 1 khub sijhawm muab;1 khub * IEEE 1588; Interface hom: GPS / BD ANT, IRIG-B / PPS kho qhov muag teeb liab;IRIG-B / PPS hluav taws xob teeb liab;TIAB SA 1588 |
| Kev ntsuas lub sij hawm | Ntau: 10ms ~ 9999.999s Qhov tseeb: 1ms |
| Hloov cov tswv yim | Ntim: 8 khub Kev cuam tshuam muaj peev xwm: DC250V / 0.5A |
| Hloov cov zis | Kom muaj nuj nqis: 6 khub, uas 2 khub yog rau qhib ceev |
| Kev sib txuas wireless | Hom interface: WIFI |
| Wired kev twb kev txuas (Ethernet kev sib txuas lus interface) | Cov naj npawb ntawm cov chaw nres nkoj: l 2 Interface hom: 100 megabytes LAN chaw nres nkoj, RJ45 |
| Fais fab mov | VVoltage: AC / DC 220V, tso cai sib txawv: -20% ~ 15% Fzaus: 47 ~ 65 Hz |
| Analog me teeb liab input | Tus naj npawb ntawm cov channel: 12 txoj kev; Interface Hom: Aviation Plug, AC Voltage |
| Analog me me teeb liab tso zis | Tus naj npawb ntawm cov channel: 12 txoj kev; Interface Hom: Aviation Plug, AC Voltage |
| USB interface | Ntim: 2 |
| Kev ua haujlwm ib puag ncig | Ua haujlwm kub: -20 ° C ~ 70 ° C Humidity: ≤95%, tsis muaj condensation |
| Lwm tus | Luj: 15 kg Loj: 360 × 480 × 190 (mm) Online interface: RJ45 Zaub: 10.4 ntikov npo1024 * 768 xim LCD zaub |