GDB-H Handheld Automatic Transformer Tig Ratio Tester
GDB-H yog ib qho khoom siv tes tuav.Nws tuaj yeem ntsuas qhov sib piv, pawg thiab theem kaum sab xis, uas yog tsim rau txhua hom kev hloov pauv xws li Z hom transformers, rectifier transformers, hluav taws xob rauv transformers, theem-hloov transformers, traction transformers, scott thiab invert-scott transformers.
●5.6inch TFT xim LCD npo, intuitively tso saib cov ntaub ntawv thiab vector daim duab.
●3-theem sim tib lub sijhawm.Ib theem hluav taws xob tawm tswv yim, nrog cov kev sib xyaw ua ke ntawm cov qauv sine yoj xeem qhov chaw.Nws generates 3-theem xeem fais fab (degree ntawm distortion yog tsawg dua 0.1%, degree ntawm symmetry yog zoo dua 0.05%) los ntawm Hi-fi fais fab amplifier.Cov txiaj ntsig kev xeem tau muaj qhov sib npaug zoo dua, thiab nws yuav tsis tshwm sim rau qhov kev txiav txim siab tsis raug.
●Ob leeg ib theem ntsuas thiab 3-theem tsis siv neeg kuaj.Nws tuaj yeem ntsuas polarity thiab theem kaum hauv ib theem lossis 3-theem xeem.Ib zaug ua tiav qhov kev ntsuas ntawm qhov sib piv, theem kaum tus nqi, yuam kev, kais txoj hauj lwm, tus nqi ntawm AB, BC, CA.Pawg naj npawb tuaj yeem raug txheeb xyuas.
●Phase angle ntsuas muaj nuj nqi.Ntsuas ntsuas lub kaum sab xis ntawm high voltage thiab low voltage.Nws kuj tseem tuaj yeem ntsuas qhov sib piv thiab lub kaum sab xis ntawm "Non-integral point" transformers.
●Cov txiaj ntsig kev xeem tau tso tawm los ntawm daim duab thiab hexagonal vector, ncaj qha qhia cov pab pawg sib txuas ntawm transformer.
●Tsis tas yuav xaiv txoj kev sib txuas lossis pab pawg sib txuas, nws tuaj yeem ntsuas Y / △, △ / Y transformer yam tsis muaj kev sib txuas sab nraud.Nws kuj tseem tuaj yeem hloov txoj hauv kev sib txuas raws li cov khoom kuaj xaiv.Transformer tsis muaj npe tuaj yeem ntsuas.
●Kev ntsuas nrawm nrawm thiab qhov sib piv qhov yuam kev ntawm txhua tus kais hloov txoj haujlwm.Tsuas yog input rated ratio ib zaug, tsis tas yuav rov hais dua cov tswv yim los xam qhov kev ua yuam kev ntawm txhua txoj hauj lwm kais.
●Nrog kev ua haujlwm ntawm ob qho tib si hloov pauv kev ntsuas thiab kev ua haujlwm voltage piv ntsuas.Kev ua haujlwm piv tuaj yeem cuam tshuam tus nqi tiag tiag ntawm qhov sib piv voltage thaum ua haujlwm.
●Nrog zoo vibration kuj.
●Qhov chaw sim ntawm qhov ntsuas no yog digital synthesis standard sine wave source.Distortion degree tsawg dua 0.1%, tsis cuam tshuam los ntawm kev siv hluav taws xob zoo.
●Me me, lub teeb yuag, yooj yim nqa.
●Built-in high-capacity rechargeable Lithium-ion roj teeb.Kev xeem tuaj yeem ua tiav yam tsis muaj lub zog.Ib zaug them tag nrho yuav siv ntau tshaj 800 zaug ntsuas tas li.
●Cov ntaub ntawv calibration tuaj yeem khaws cia, thiab qhov tshwm sim tuaj yeem hloov mus rau PC los ntawm U disk.
●TTR ntsuas ntau: 0.8 ~ 10000.
●Kev ntsuas ceev ceev: kev ntsuas peb theem tuaj yeem ua tiav hauv 60 vib nas this.
●Kev ntsuas qhov tseeb:
Kev ntsuas qhov tseeb ntawm HV sab: 0.05%
Kev ntsuas qhov tseeb ntawm LV sab: 0.1%
Lub kaum sab xis ntsuas qhov tseeb: 0.1 °
TTR ntsuas qhov tseeb: 0.1% (0.8-3000)
0.2% (3000-10000)
●Qhov hnyav: txog 3Kg.
| GDB-H instrument | 1pc ua |
| Accessory Case | 1pc ua |
| HV Test Lead nrog clamp | 1set ib |
| LV Test Lead nrog clamp | 1set ib |
| Fuse | 2 pcs |
| Charger | 1pc ua |
| Cov neeg siv phau ntawv qhia | 1pc ua |
| Factory test report | 1pc ua |