Lub peev xwm thauj khoom ntawm Cov Txheej Txheem Txheej Txheem Txheej Txheem Tam Sim No yog tsim rau kev tiv thaiv busbar thiab kev txheeb xyuas qhov sib piv tam sim no transformer, thiab lwm yam, thiab tuaj yeem kho tam sim no relays thiab keyboards.Nws yog tsuas yog siv rau kev sim cov khoom xws li kev tiv thaiv busbar thiab ntau yam tam sim no transformer piv.Vim tsis muaj zog noj, muaj peev xwm loj tus kheej twisting regulator thiab high-permeability magnetic core, lub converter muaj ib tug loj tso zis hwj chim.Qhov zoo ntawm qhov me me thiab lub teeb yuag.
"Cov ntsiab lus tsis txaus ntseeg" ntawm qhov ntsuas hluav taws xob siab tam sim no:
Vim li cas thiaj siv Cov Txheej Txheem Txheej Txheem Tam Sim No los ntsuas qhov kev tiv thaiv hluav taws xob ntawm cov hluav taws xob hluav taws xob?
GDSL-D Seriese Digital Primary Current Injection Test Set
1.Hauv kev tiv thaiv kev sim thiab kev hloov pauv ntawm cov khoom siv hluav taws xob, ntau cov khoom siv hluav taws xob tam sim no yuav tsum tau ntsuas qhov ntsuas qhov tsis kam ntawm Circuit Court.Circuit Court breakers yog cov khoom siv hluav taws xob tseem ceeb hauv cov tshuab hluav taws xob.Lub teb chaws tus qauv GB thiab lub zog hluav taws xob kev lag luam tus qauv DL / T qhia txog qhov ntsuas ntawm qhov kev tiv thaiv lub voj tsis kam ntawm lub Circuit Court breaker: nws yuav tsum ntsuas los ntawm DC voltage poob txoj kev, thiab tam sim no tsis tsawg dua 100A.
2.Qhov kev tiv thaiv ntawm cov hluav taws xob hluav taws xob ntawm cov hluav taws xob hluav taws xob feem ntau yog nyob ntawm qhov kev tiv thaiv kev tiv thaiv ntawm kev sib tiv tauj thiab kev sib cuag zoo li qub ntawm Circuit Court breaker.Lub xub ntiag ntawm kev sib cuag yuav ua rau kom poob thaum tus neeg xyuas pib muaj zog, yog li ua kom qhov kub thiab txias ntawm qhov sib cuag, thiab tus nqi ntawm tus nqi no ncaj qha cuam tshuam rau lub peev xwm nqa tam sim no thaum lub sijhawm ua haujlwm ib txwm, yog li cuam tshuam rau lub peev xwm luv luv.Circuit Court tam sim no nyob rau hauv degree.Yog li ntawd, tus nqi kuj ntawm txhua theem ntawm Circuit Court breaker yog ib qho tseem ceeb cov ntaub ntawv rau lub installation, overhaul thiab zoo txais ntawm lub Circuit Court breaker.
3.Kev tiv thaiv kev tiv thaiv ntawm Circuit Court breaker tau ntsuas yav dhau los uas siv DC ob sab caj npab choj.Txawm li cas los xij, thaum tus choj ob txhais tes siv los ntsuas qhov kev tiv thaiv ntawm cov hluav taws xob hluav taws xob ntawm cov hluav taws xob hluav taws xob, vim tias tam sim no los ntawm ob sab caj npab ntsuas Circuit Court tsis muaj zog heev, nws yog ib qho nyuaj rau muaj cov oxide zaj duab xis nrog kev ua haujlwm loj. , thiab nws yog ib qho nyuaj rau kev ntsuas tus nqi kuj loj heev, tab sis cov oxide zaj duab xis yog ib qho yooj yim Nws ruptures nyob rau hauv siab tam sim no thiab yuav tsis cuam tshuam txoj kev ntawm ib txwm tam sim no.Yog li ntawd, thaum siv DC voltage poob txoj kev rau kev sim, qhov tam sim no yuav tsum tsis txhob me dhau.
4.Muaj ntau txoj hauv kev los ntsuas kev tiv thaiv kev tiv thaiv.Cov kws tshawb fawb txawv teb chaws xav kom siv cov khoom siv hluav taws xob quantum los ntsuas kev tiv thaiv kev tiv thaiv, ntsuas kev tiv thaiv kev tiv thaiv los ntawm electrolytic cell method, thiab ntsuas kev tiv thaiv kev tiv thaiv los ntawm peb txoj kev sib haum xeeb.Cov txheej txheem no feem ntau yog siv rau kev tshawb fawb txog hluav taws xob nyob rau hauv lub chaw kuaj mob.Hauv engineering, plaub-terminal txoj kev feem ntau yog siv los ntsuas qhov kev tiv thaiv tiv thaiv ntawm cov neeg sib cuag tiag tiag.
HVHIPOT GDSL-D series digital display high current generator (upflow device) yog ib qho khoom siv tsim nyog rau txhua qhov chaw ntawm lub neej hauv hluav taws xob debugging qhov twg siab tam sim no.Nws yog siv nyob rau hauv fais fab nroj tsuag, substations, hluav taws xob khoom tsim cov nroj tsuag, kev tshawb fawb, thiab kev sim.Cov chav xws li cov chav ua haujlwm yog nyob rau lub sijhawm luv lossis tsis sib xws, uas muaj cov yam ntxwv ntawm qhov me me, lub teeb yuag, kev ua haujlwm zoo, thiab kev siv yooj yim thiab tu.Feem ntau yog siv rau kev tiv thaiv tsheb npav thawj zaug thiab pov thawj ntawm ntau yam tam sim no transformers, lub cev muaj zog tiv thaiv, cua hloov pauv, hloov cov khoom, cov khoom siv hluav taws xob, cov ntxaij vab tshaus, thiab lwm yam.