GDWG-V SF6 Gas Leak Detector (IR hom, Ob chav zaub)
GDWG-V SF6 Gas Leak Detector yog infrared liab hom leak detector (NDIR thev naus laus zis) nrog ob chav zaub.Nws yog xim INCELL TFT zaub thiab lub sijhawm tiag tiag qhia SF6 concentration.Nws pom sai sai SF6 breaker, GIS to point thiab txhua xyoo to tus nqi zoo thiab ntau.Nws yog ib qho khoom siv zoo tsim rau chav ua haujlwm fais fab, kev teeb tsa thiab kho dua tshiab, lub koom haum kuaj hluav taws xob.
●High Voltage Switch Khoom siv
●Rotor vane ntawm helicopter
●Gas kis tau tus mob
●Txhawm rau txhawm rau txhawm rau tua hluav taws
●Kev tshawb fawb qhov cua tshuab ntawm Cov Tsev
●Txhawm rau txheeb xyuas qhov txaus ntshai
●Tsis muaj hluav taws xob.
●Tsis tas yuav hloov lub siab siab siab ntshiab argon roj tsis tu ncua.
●Tsis tas yuav mus rau qhov siab siab gas.
●Tsis tas yuav hloov cov sensors tsis tu ncua, raug nqi zoo.
●Kev ua haujlwm ruaj khov, tsis tshua muaj nqi kho.Tsis tas yuav ua linear calibration txhua xyoo.
●Tsis cuam tshuam los ntawm ya raws thiab ib puag ncig muaj kuab paug.
●rhiab heev, mus txog 0.01ppmv.
●Thaum loj heev los yog SF6 roj concentration yog mus txog 100%, nws yuav tsis muaj kuab paug los yog puas.
●Xim TFT Hauv-Cell npo, ob chav zaub, pom hauv tshav ntuj.
●Built-in Lithium roj teeb.
●Cov neeg siv lub tswb nrov nrog lub suab thiab lub teeb.
●Siab rhiab heev thiab zoo stability.
●Kev ntsuas ceev ceev, lub sij hawm yog mus txog 3s.
●Kub thiab siab them nyiaj.
●Tsuas yog cov lus teb rau SF6 roj, tsis yog rau lwm cov roj.
●Cov yam ntxwv uas tsis yog-gas kev ntsuas ntsuas kom ntseeg tau tias tsis muaj cov tshuaj lom sensor yuav tshwm sim ntawm txhua qhov kev xav.
●Lub sensor qhov kub thiab txias chamber tuaj yeem xyuas kom meej tias lub sensor tsis muaj qhov kub thiab txias ntawm qhov ntsuas kub.
●Me me, nqa tau yooj yim, haum rau kev ua haujlwm ntawm qhov chaw.
●Nrog gasbag tsis-slip pluaj, yooj yim dua rau nqa.
●Cov ntaub ntawv khaws cia txog 100 pawg.
●Super-lub teeb aluminium nrog tag nrho shielding plhaub.
●Sab nrauv pob siv engineering yas, nrog dej-pov thawj, plua plav-pov thawj.
●Kev ntsuas txoj cai: Tsis-dispersive infrared sensor (NDIR)
●Kev ntsuas ntau: 0-2000ppmv SF6 lossis 0-50ppmv
●Kev daws teeb meem: 0.1ppmv lossis 0.01ppmv
●Qhov tseeb: ± 2% FS (0-1000ppm)
●Repeatability yuam kev: ≤ ± 1%
●rhiab heev: 0.1ppmv
●Lub sij hawm teb: ≤2s
●Lub sij hawm rov qab: ≤5s
●Kev ruaj ntseg: ≤ ± 20ppm, ntau tshaj 1000hours
●Zero hloov: ≤ ± 1% (FS / xyoo)
●Linear yuam kev: ≤ ± 1%
●Cia kub: -20 ~ + 60 ℃
●Ua haujlwm kub: -20 ~ + 50 ℃
●Qauv qauv: Ua-nyob rau hauv electromagnetic diaphragm twj tso kua mis, tsis siv neeg slot-in hom, ntws mus txog 1L / min.
●Ua hauj lwm voltage: 220VAC ± 10%, 50Hz Los yog Built-in Li-roj teeb, 8 teev ua haujlwm.
●Dimension: 160 × 220 × 70mm, tes phom 106mm * 170mm * 120mm.
●Qhov hnyav: chav tsev loj txog 1.5kg, tes phom txog 0.5kg