GDP-311CAW 3-in-1 SF6 Quality Analyzer
GDP-311PCAW SF6 gas zoo analyzer yog ib qho khoom siv portable tsim los ntsuas SF6 roj purity, dew point, muaj pes tsawg leeg, CF4 cov ntsiab lus thiab cov ntsiab lus cua.Cov tub ntxhais tivthaiv nrog NDIR sensor tsim los ntawm European sensor tuam txhab los kuaj SF6 roj purity, RC sensor tsim los ntawm Vaisala, Finland los ntsuam xyuas dew point, NDIR sensor tsim los ntawm Smartgas, lub teb chaws Yelemees los kuaj SF6 roj decomposition khoom - CF4.huab cua sensor txais itg technology.Tsis tas li ntawd, peb kuj tau txais kev tshaj lij kho vajtse chips thiab software zoo heev algorithms ntawm STMicroelectronics.
●SF6 tsom xam rau lub zog system
●SF6 Gas Lub tog raj kheej Gas zoo kuaj
●Kev ntsuas zoo ntawm SF6 roj rau kev rov qab thiab rov siv dua
●High purity gas manufacturing
●Semiconductor kev lag luam qhuav roj muab
●Kev tshawb nrhiav thiab kev tsim kho siv
●Nrog cov khoom siv high-precision sensor thiab nws tus kheej-calibration muaj nuj nqi, cov txiaj ntsig kev xeem tau raug ntau dua txhua xyoo.
●Nrog cov khoom siv polymer tsim thoob plaws hauv cov raj xa dej los ntawm Legris, Camozzi thiab Swagelok, xyuas kom tsis muaj qhov cuam tshuam ntawm phab ntsa, thiab kev ntsuas ceev ceev.
●Roj-dawb stainless hlau regulating valve yog saws los xyuas kom meej qhov tseeb.
●Advanced software algorithm txhim kho qhov kev xeem raug ntawm cov sensors txawv teb chaws.
●Nrog cov ntaub ntawv yooj yim configuration.Cov neeg siv tuaj yeem sib sau cov khoom seem yooj yim dua.
●Fais fab mus ntes, tsis xav tau oscillation.
●Kub conversion thiab siab cov ntaub ntawv kho.
●Fuzzy xam tshuab.
●High-power lithium fais fab mov system tuaj yeem paub AC DC ob chav fais fab mov.Tsis xav tau rau ntawm qhov chaw AC fais fab mov.Lithium roj teeb tuaj yeem ua haujlwm tsis tu ncua rau ntau tshaj 8 teev ib leeg.
●Anti-electromagnetic cuam tshuam Circuit Court tsim, kom ntseeg tau cov khoom lag luam.
●USB kev sib txuas lus, serial kev sib txuas lus thiab wireless kev sib txuas lus modules yuav txuas mus rau lub PC kev sib txuas lus thiab luam ntawv functions.(yeem)
●Kev khaws cia loj, uas tuaj yeem paub txog kev khaws cia ntawm 1000 pawg ntawm cov ntaub ntawv.
●Gas txoj kev pretreatment muaj nuj nqi tuaj yeem ua kom huv lub raj xa dej ua ntej kev sim ua haujlwm, uas ua rau lub sijhawm sim luv.(yeem)
●Nrog kev tiv thaiv ib puag ncig muaj nuj nqi.Cov cuab yeej muaj qhov ntsuas roj rov ua haujlwm, uas tuaj yeem rov ua dua cov pa ntsuas sulfur hexafluoride.(yeem)
●purity ntsuas qhov tseeb yog 0.5% nyob rau hauv tag nrho cov ntau yam, uas yuav siv tau los ntsuas siab concentration SF6 roj thiab 70% SF6 roj.
●Cov zaub ntawm qhov zoo tshaj plaws kev xeem ntws cheeb tsam yog meej thiab intuitive.Cov neeg siv tuaj yeem kho cov roj ntws ncaj qha thiab nrawm.
●Cov cua nkag tau txais cov qauv tsim ntawm cov khoom me me rau nws tus kheej sealing sib koom ua ke, yog li txoj kev ntsuas cua yuav tsis xau thaum nws tawg.