GDJF-2007 Digital Partial Discharge Analyzer
GDJF-2007 Digital Partial Discharge Analyzer yog dav siv rau kev kuaj xyuas ib feem ntawm cov khoom siv hluav taws xob siab xws li fais fab transformers, ntsuas transformer, HV Circuit Court breaker, GIS, Zinc oxide surge arrester, fais fab cable.Nws kuj tseem tuaj yeem ua hom kev sim thiab saib xyuas kev ua haujlwm rwb thaiv tsev.
Nws suav nrog lub ntsiab chav tsev, PD software, tam sim no transformer, input unit, calibration mem tes generator, input adapter, kav hlau txais xov amplifier thiab kev twb kev txuas cable thiab lwm yam.
●12 nti LCD zaub, nrog cov qauv tsim, rugged thiab ruaj khov, yooj yim siv.
●Muaj zog tiv thaiv kev cuam tshuam, muaj tseeb.Siv cov thev naus laus zis lim dej, kev cuam tshuam hauv cheeb tsam tuaj yeem raug tshem tawm tau zoo, thiab kev ntsuas qhov tso tawm ib nrab tuaj yeem pom tau hauv ib puag ncig cuam tshuam.
●Multi-channel tau txais cov ntaub ntawv.Ib qho screen tuaj yeem tso saib 2 channels lossis 4channels waveform.
●Muaj zog software muaj nuj nqi.Nrog rau kev ntsuas PD, kev tsom xam, PD rov tso tawm lub sijhawm N ntsuas, ntsuas thiab tiv thaiv kev cuam tshuam, tiv thaiv kev cuam tshuam.Dawb xaiv ntawm ellipse, txoj kab ncaj nraim thiab sinusoidal zaub hom.Ntsuas thiab Saib xyuas cov mem tes tawm ntawm qhov rais, thiab ntsuas qhov hluav taws xob thiab tam sim no, ib feem ntawm qhov paug tuaj yeem ntsuas tib lub sijhawm.Tag nrho cov ntaub ntawv xeem ntawm 2 channel tuaj yeem khaws cia raws sijhawm.Kev ntsuas waveform tuaj yeem khaws cia, rov ua dua thiab tshuaj xyuas.Qhov nce ntau ntawm txhua tus channel tuaj yeem hloov kho ntxhib thiab kho kom zoo.Digital qhov rais-qhib tshuab, kom tsis txhob muaj kev cuam tshuam ntawm kev ntsuas.Theem qhov rais qhib, ib lub qhov rais thiab ob lub qhov rais tuaj yeem xaiv.Lub qhov rais tuaj yeem qhib dawb hauv 360degree.
●Ua raws li IEC60270 tus qauv.
●Capacitance ntau: 6pF-250μF
●rhiab heev: 0.1pc
●Kev ntsuas channel: 2 lossis 4pcs ywj siab raws
●Sampling raug: 12Bit
●Sampling tus nqi: Max.100MHz ib channel
●Kev ntsuas ntau: 0.1pc-10000nc.
●Dynamic ntau:> 80db.
●Kev ntsuas zaus band: 10kHz-1MHz ntawm 3db.
●Ntau zaus ntawm kev xeem lub zog: 50-400Hz.
●Programmable lim
Tsawg zaus: 10K, 20K, 40K, 80K;
High zaus: 100K, 200K, 300K, 1000K.
●Environmental kub: -15 ℃ - 50 ℃
●Cov av noo: ≤ 95% (20 ℃)
●Qhov siab: ≤3000m.
●Muaj peev xwm cuam tshuam: 5000V ntawm txhua qhov chaw nres nkoj thiab lub zog hluav taws xob (zoo, tsis zoo thiab AC)
●Lub zog tawm tswv yim: AC220V ± 10%, 45-65Hz, lub zog <500W.
●Qhov hnyav: txog 15kg.
●Loj: 58 * 36 * 32CM