GDBR-P Transformer Load Tsis-load thiab Peev Xwm Tester
●Ntsuas transformer Tsis muaj-load tam sim no, Tsis muaj-load poob, luv Circuit Court voltage, luv Circuit Court poob thiab muaj peev xwm.
●Peb txoj kev sim ntsuas.
●Thaum ua peb theem transformer Tsis muaj-load, load test, lub ntsuas yuav txiav txim yog hais tias cov hlau yog lawm, thiab qhia peb theem voltage, tam sim no vector daim duab.
●Tiav load xeem nyob rau hauv 1600kVA hauv qab no transformer tag nrho tam sim no rau ib lub tshuab.Ua kom tiav 2500kVA hauv qab qhov kev faib tawm transformer load test nyob rau hauv 1/3 rated tam sim no (Raws li 1/3 rated tam sim no, lub twj paj nruag tuaj yeem hloov mus rau qhov poob tsis tau raws li qhov ntsuas tam sim no.)
●Txhua qhov kev xeem tau raug kho kom raug.Qhov ntsuas tsis siv neeg kho raws li hauv qab no, hloov kho waveform, kho qhov kub thiab txias, tsis ntsuas qhov ntsuas hluav taws xob thiab tsis ntsuas tam sim no kho.Cov qhabnias xeem yog qhov tseeb dua.
●320 * 240 siab brightness LCD npo, nrog brightness hloov.Kov cov nyees khawm ua haujlwm yooj yim dua.
●Lub sijhawm tiag tiag lub sijhawm, sau hnub xeem tau txais, tsim nyog rau kev khaws cia thiab tswj cov txiaj ntsig kev xeem.
●Built-in vaj huam sib luag hom thermal tshuab luam ntawv, ceev luam ntawv tau txais txiaj ntsig.
●Fais fab cia cia thiab xauj cov ntaub ntawv (cov khoom siv ntsuas, ntsuas ntsuas, ntsuas lub sijhawm) ua haujlwm.Khaws txog li 500 pawg kev xeem, cov ntaub ntawv xa mus online rau PC.
●Tso cai ncua kev ntsuas rau sab nraud voltage transformer thiab tam sim no transformer.Ntsuas cov khoom ntsuas ntawm ib qho kev ntsuas.
1. Cov khoom kuaj
●RMS of three phase voltage: Uab, Ubc, Uca.
●Tus nqi nruab nrab ntawm peb theem AC voltage: Uab, Ubc, Uca.
●RMS of three phase current: Ia, Ib, Ic.
●Qhov feem pua ntawm Tsis-load poob thiab Tsis muaj-load tam sim no: Po, Io%.
●Load poob, impedance voltage feem pua, luv Circuit Court impedance: Pt, ekt, Zt.
●Load poob, impedance voltage feem pua thiab luv Circuit Court impedance ntawm tej qhov kub thiab txias.
●Transformer muaj peev xwm thiab txiav txim siab muaj peev xwm.
2. Cov yam ntxwv tseem ceeb
●Kev ntsuas tam sim no: 100mA-60A, qhov tseeb: chav kawm 0.2.
●Kev ntsuas hluav taws xob ntau: 10V-650V, qhov tseeb: chav kawm 0.2.
●Sab nraud transformer tuaj yeem nthuav dav qhov ntsuas qhov ntsuas.
●Kev ntsuas ntau zaus: 40-65Hz, qhov tseeb: chav kawm 0.2.
●Lub zog hluav taws xob: AC220V ± 10%.
Chav tsev loj | 1pc ib |
Fais fab qaum | 1pc ib |
Clamp kuaj kab | 1set ib |
Tshwj xeeb luv luv-circuit cable | 1pc ib |
Cov neeg siv phau ntawv qhia | 1pc ib |
Factory test report | 1pc ib |