Cable Fault Location System

  • RE-MCF Trolley-Type Cable Fault Comprehensive Test System

    RE-MCF Trolley-Type Cable Fault Comprehensive Test System

    RoBot-Eye Series fully integrated cable fault testing system combines multiple functions, including low-voltage pulse distance measurement, high-voltage pulse current distance measurement, acoustic-magnetic induction pinpointing, audio reception pinpointing, and step-voltage pinpointing. It is primarily used for locating faults such as broken wires, short circuits, and ground leakage faults (with ground insulation resistance below 0.5 megohms) in high- and low-voltage buried power cables. It can also identify high-resistance ground faults, flashover ground faults, and detect the depth and path direction of buried cables.

  • HV-OWS-63 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of Cables

    HV-OWS-63 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of Cables

    HV-OWS-63 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of 10KV Cables is an integrated partial discharge location and management system. Partial discharge test with DAC waves,Test frequency varies from 50Hz to hundreds of Hertz under damping AC voltage.

  • GD-3134D+GD-2134L  UHV Cable Sheath Fault Locator

    GD-3134D+GD-2134L UHV Cable Sheath Fault Locator

    GD-3134D UHV cable sheath fault locator is an intelligent instrument with innovative features and high performance that integrates computer technology and digital signal processing technology. The UHV cable sheath fault locator can measure the resistance current in the faulty cable in the wellbore through the current sensor and locate the cable fault point in sections. For cables laid on cable supports in large quantities in cable tunnels, the DC voltage can also be measured by high-voltage probes to determine the fault point.

    The UHV cable sheath fault locator needs to be used in conjunction with the GD-2134L UHV cable sheath fault signal generator, which can provide high-voltage pulse signal source for the fault location of the UHV cable sheath, to complete the precise location of the UHV cable sheath grounding fault.

  • GD-4138H Cable Fault Locating System

    GD-4138H Cable Fault Locating System

    The trolley-type cable fault locating system highly integrates traditional and independent cable fault testers, integrated high-frequency and high-voltage power supplies, multiple pulse generators, path transmitters, insulation resistance testers, and other independent units. The system is used for rough testing of various fault distances, path finding, and precise fault location of power cables. The testing software automatically recognizes the card position and reads the fault distance, truly making the testing of cable faults light, simple, efficient, and safe. Provide convenience for rapid testing of power cable faults.

  • GD-4136H Cable Fault Locating System

    GD-4136H Cable Fault Locating System

    GD4136H Cable Fault system is an important tool to maintain all kinds of cables. 

     

     

  • GD-2136H Cable Fault Locating System

    GD-2136H Cable Fault Locating System

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables.

     

  • GDTG-600A Cable Fault Locator

    GDTG-600A Cable Fault Locator

    GDTG-600A Cable Fault Locator is a portable open-air instrument working on TDR and bridge methods, adopting advanced micro-electronics technology. It is designed to locate accurate fault points in such cables as telecommunication plastic cable or user’s lead covered wire, while the faults include break, mix, earthing, defective insulation, or poor connecting. It is an ideal function-stable instrument for the open-air operator to improve work efficiency; in addition, it can also be used for circuitry project checking electric property testing of the cable. 

     

     

     

     

     

Send your message to us:

Write your message here and send it to us